[Use of artificial intelligence in screening for diabetic retinopathy at a tertiary diabetes center]
Sebastian Paul1, Allam Tayar1, Ewa Morawiec-Kisiel1
1Klinik und Poliklinik für Augenheilkunde, Universitätsmedizin Greifswald, Ferdinand Sauerbruch Str., 17475, Greifswald, Deutschland.
Background:
In 2018, IDx-DR was approved as a method to determine the degree of diabetic retinopathy (DR) using artificial intelligence (AI) by the FDA.
Methods:
We integrated IDx-DR into the consultation at a diabetology focus clinic and report the agreement between IDx-DR and fundoscopy as well as IDx-DR and ophthalmological image assessment and the influence of different camera systems.
Results:
Adequate image quality in miosis was achieved more frequently with the Topcon camera (n = 456; NW400, Topcon Medical Systems, Oakland, NJ, USA) compared with the Zeiss camera (n = 47; Zeiss VISUCAM 500, Carl Zeiss Meditec AG, Jena, Germany). Overall, IDx-DR analysis in miosis was possible in approximately 60% of the patients. All patients in whom IDx-DR analysis in miosis was not possible could be assessed by fundoscopy with dilated pupils. Within the group of images that could be evaluated, there was agreement between IDx-DR and ophthalmic fundoscopy in approximately 55%, overestimation of severity by IDx-DR in approximately 40% and underestimation in approximately 4%. The sensitivity (specificity) for detecting severe retinopathy requiring treatment was 95.7% (89.1%) for cases with fundus images that could be evaluated and 65.2% (66.7%) when all cases were considered (including those without images in miosis which could be evaluated). The kappa coefficient of 0.334 (p < 0.001) shows sufficient agreement between IDx-DR and physician's image analysis based on the fundus photograph, considering all patients with IDx-DR analysis that could be evaluated. The comparison between IDx-DR and the physician's funduscopy under the same conditions shows a low agreement with a kappa value of 0.168 (p < 0.001).
Conclusion:
The present study shows the possibilities and limitations of AI-assisted DR screening. A major limitation is that sufficient images cannot be obtained in miosis in approximately 40% of patients. When sufficient images were available the IDx-DR and ophthalmological diagnosis matched in more than 50% of cases. Underestimation of severity by IDx-DR occurred only rarely. For integration into an ophthalmologist's practice, this system seems suitable. Without access to an ophthalmologist the high rate of insufficient images in miosis represents an important limitation.