Related Experiment Video
Updated: Oct 5, 2025

Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation
Published on: October 20, 2016
Real-time radial tagging for quantification of left ventricular torsion
Elham Mohammadi1, Abbas Nasiraei-Moghaddam1, Martin Uecker2,3,4,5
1Department of Biomedical Engineering, Amirkabir University of Technology (Tehran Polytechnic), Tehran, Iran.
Purpose:
To develop a real-time radial tagging MRI for accurate measurement of rotational motion and twist of the left ventricle (LV).
Methods:
A FLASH-based radial tagging sequence with an undersampled radial reading scheme was developed for both single and double-slice imaging in real-time. The Polar Fourier Transform was used for reconstruction to push the undersampling artifacts out of a reduced FOV. The developed technique was used to image five normal subjects during rest, plus one during both exercise and rest conditions. LV rotational motions were estimated for five consecutive cardiac cycles in all cases. The process was validated using a numerical phantom. The real-time measurement of global rotational motion was compared with those measured from a non-real-time exam using linear regression analysis and the Bland-Altman plot.
Results:
The real-time acquisition was performed successfully with a temporal resolution of 46.2 ms. Image quality was sufficient for the reproducible calculation of rotation at rest and exercise. The feasibility of double-slice acquisition on human was further studied and a real-time twist of the left ventricle was demonstrated. The difference between LV global rotations from real-time and non-real-time approaches was 0.27 degrees. A significant reverse recoiling, induced by exercise, was reproducibly measured by the technique.
Conclusion:
A real-time radial tagging MRI technique was developed based on the undersampled radial acquisition and Polar Fourier Transform reconstruction, for accurate measuring of the heart rotational motion and twist. The technique was able to extract a meaningful change of diastolic recoiling under stress test conditions during physical activities (cycling).
More Related Videos
07:21Magnetic Resonance Derived Myocardial Strain Assessment Using Feature Tracking
Published on: February 12, 2011
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
Related Concept Videos
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps: