The Optimized Oxford Hip Skeletal Maturity System Proves Resilient to Rotational Variation
Julio C Castillo Tafur1, Ryan J Furdock1, Abdus Sattar2
1Department of Orthopaedic Surgery, Rainbow Babies and Children's Hospital at Case Western Reserve University School of Medicine.
Background:
The recently described optimized Oxford skeletal maturity system utilizes anteroposterior (AP) hip radiographs to accurately, rapidly, and reliably estimate skeletal maturity. However, in the real-world setting, significant positional variation in AP hip radiographs may influence the accuracy of optimized Oxford skeletal age estimates. We sought to evaluate the consistency of skeletal age estimations using the optimized Oxford system between differently rotated radiographs.
Methods:
Thirty normal computerized tomography scans of males (15 children, 9 to 15 y) and females (15 children, 8 to 14 y) were obtained retrospectively, converted into 3D reconstructions, and then used to produce simulated hip radiographs in five different rotational positions. The optimized Oxford system was applied to the 150 simulated AP hip radiographs (5 differently rotated views of 30 hips) to produce a skeletal age estimate for each.
Results:
Rotational position did not have a statistically significant effect on the skeletal age (P=0.84) using 1-way repeated measures analysis of variance. Of the 5 radiographic parameters in the optimized Oxford system, only greater trochanter height showed significant rotational variation after Greenhouse-Geisser correction (F2.58, 74.68=5.98, P<0.001). However, post hoc analyses showed that the greater trochanter height obtained at the most centered position was not different from the other 4 rotational positions (P>0.05 for all).
Conclusion:
The optimized Oxford skeletal maturity system is resilient to rotational variation. Mildly to moderately rotated radiographs obtained in the modern clinical setting can be used for skeletal age estimation by this method, broadening the clinical usage of this system.
Level Of Evidence:
Level III-diagnostic study.
Related Concept Videos
Eccentric Axial Loading in a Plane of Symmetry
Changes in the Appendicular Skeleton with Age
Initially, the limb buds consist of a core of mesenchyme covered by a layer of ectoderm. The ectoderm at the end of the limb bud thickens to form a narrow crest called the apical ectodermal ridge. This ridge stimulates the underlying...
General Case of Eccentric Axial Loading
Consider a member subjected to equal and opposite forces that are applied along a line that does not coincide with the member's neutral axis. In unsymmetrical...
Normal Strain under Axial Loading
Introduction to the Skeletal System
Components of the Skeletal System
Bone, or osseous tissue, is a hard connective tissue that forms an internal support structure for the human body. Bones shield vulnerable organs and soft tissue from external forces. For example, the vertebral bones protect and support the spinal cord.
Cartilage, a semi-rigid connective tissue found in regions such as...
Kinematic Equations for Rotation
For instance, imagine a point A on a rigid body engaged in circular motion. The translational velocity of this particular point can be calculated by taking the time derivatives of the displacement equation, which essentially measures the...