Related Experiment Video
Updated: Oct 4, 2025

Fabrication and Characterization of High-Q Silicon Nitride Membrane Resonators
Published on: August 8, 2025
Using silicon disk resonators to measure mechanical losses caused by an electric field
Y Yu Klochkov1, L G Prokhorov2, M S Matiushechkina3
1Faculty of Physics, Lomonosov Moscow State University, 119991 Moscow, Russia.
Abstract:
Several projects of the next generation gravitational-wave detectors use the high purity monocrystalline silicon test masses. The electric field of the actuator that is applied to correct the position of the silicon test mass causes additional mechanical losses and associated noise. Disk mechanical resonators are widely used to study mechanical losses in multilayer optical coatings that are deposited on the test masses of gravitational-wave detectors. We use silicon disk resonators to study losses caused by an electric field. In particular, the dependence of mechanical losses on the resistivity of silicon is investigated. The resonator is a thin commercial silicon wafer in which a low frequency nodal diameter mode is excited. A DC voltage is applied between the wafer and a nearby electrode. We use two measurement configurations. In the first configuration, the dependence of losses on the resistance in the voltage supply circuit is investigated. The dependence of losses on the resistivity of silicon is investigated in the second configuration. We propose a model that relates the electric field induced mechanical loss in disk resonators to the resistivity of the material. Measurements are carried out for low and high resistivity silicon wafers. The measurement results are compared with calculations. Based on these studies, it is possible to estimate the loss and noise of the test masses of gravitational-wave detectors associated with electrostatic actuators.
Related Concept Videos
RLC Circuit as a Damped Oscillator
Consider a series RLC circuit. Here, the presence of resistance in the circuit leads to energy loss due to joule heating in the resistance. Therefore, the total electromagnetic energy in the circuit is no longer constant and decreases with time. Since the magnitude of charge, current, and potential difference continuously decreases, their oscillations are said to be damped. This is...
Magnetic Damping
If, however, the bob is a slotted metal plate, the magnet produces a much smaller effect. When a slotted metal plate enters the field, an emf is induced by the change in flux; however, it is less effective because the slots limit the...
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...