Related Experiment Video
Updated: Oct 4, 2025

Development of a Virtual Reality Assessment of Everyday Living Skills
Published on: April 23, 2014
Inpatient Rehabilitation Facility Change in Self-Care and Change in Mobility Quality Measures: Development and
Anne Deutsch1, Lauren Palmer2, Molly Vaughan3
1Comprehensive Health Innovation, Research, and Policy Division, RTI International, Waltham, Massachusetts; Center for Rehabilitation Outcomes Research, Shirley Ryan AbilityLab, Chicago, Illinois; Department of Physical Medicine and Rehabilitation, Feinberg School of Medicine, Northwestern University, Chicago, Illinois.
Objective:
To describe the development, implementation and reliability and validity testing of the inpatient rehabilitation facility (IRF) Change in Self-Care and Change in Mobility quality measures.
Design:
We describe the activities involved in developing and implementing the 2 facility-level quality measures, including public comment opportunities. We examined facility-level reliability using split-half testing and Pearson product-moment correlations, Spearman rank correlations, and intraclass correlation coefficients (ICC2,1). We examined validity by comparing facility-level quality measure scores and facility disease-specific certification status.
Setting:
All 1117 IRFs in the United States with at least 20 Medicare stays that ended in 2017.
Participants:
Facility-level quality measure scores (N=1117) were derived from data from 427,517 (self-care) and 427,956 (mobility) Medicare fee-for-service and Medicare Advantage IRF patient stays in 2017.
Interventions:
Not applicable.
Main Outcome Measures:
Facility-level Change in Self-Care and Change in Mobility quality measure scores and facility Disease-Specific Certification for Stroke Rehabilitation from The Joint Commission were used in validity analysis.
Results:
The split-half quality measure scores showed strong, positive correlations for the facility-level self-care (Pearson=0.903, Spearman=0.884, ICC=0.903, P<.0001) and mobility (Pearson=0.903, Spearman=0.884, ICC= 0.903, P<.0001) quality measure scores, providing evidence of reliability. ICCs remained strong when stratifying by provider volume. IRFs with stroke certification had slightly higher mean and median quality measure scores than IRFs without certification, and IRFs with the higher quality measure scores tended to have a higher percentage of certified IRFs.
Conclusions:
Our analyses support the reliability and validity of the Change in Self-Care and Change in Mobility quality measure scores in IRFs.
More Related Videos
06:52Assessment of Dependence in Activities of Daily Living Among Older Patients in an Acute Care Unit
Published on: September 30, 2020
06:28Biomechanical Changes Related to Low Back Pain: An Innovative Tool for Movement Pattern Assessment and Treatment Evaluation in Rehabilitation
Published on: December 13, 2024
Related Concept Videos
Restorative Care
Documentation in Long-Term and Home Healthcare Setting
Long-Term Care Facilities
Reliability and Validity
Specialized Care Centers and Settings-II
Rural health centers are specialized care facilities in remote locations with very few medical personnel. The primary care providers who run the centers are mostly Registered Nurse Practitioners. Here, emergency treatment is provided to critically ill or injured patients before they are transferred to the closest hospital. Fortunately, due to advancement in technology, many rural healthcare facilities and professionals have easy access to diagnostic and treatment...