Impact of monitoring surface temperature during pulmonary vein isolation in a second-generation hot balloon system
Hiroshi Fukunaga1, Yukio Sekiguchi1, Sou Asano1
1Department of Cardiology, Sakakibara Heart Institute, 3-16-1 Asahi-cho, Tokyo 183-0003, Japan.
Background:
A surface temperature sensor can be used to visualize the effect of hot balloon (HB) catheters. This study evaluated the efficacy and safety of a second-generation HB system with surface temperature monitoring in patients with atrial fibrillation (AF).
Methods:
Twenty patients (age: 69.6 ± 9.7 years, 11 male participants) who underwent first-time pulmonary vein isolation (PVI) using a second-generation HB were included. For each pulmonary vein (PV), the acute isolation rate and effective therapeutic range of surface temperature were investigated.
Results:
Eighty-three PVs (including three right middle PVs) were isolated in 20 patients using an HB with a surface temperature sensor. Sixty-eight PVs were isolated using the first application. Fifteen PVs (left superior PV [LSPV], n = 7 [35%]; left inferior PV, n = 2 [10%]; right superior PV, n = 3 [15%]; right inferior PV, n = 3 [15%]) showed early intraoperative reconduction and required second applications. One LSPV required radiofrequency touch-up at the carina. The optimal balloon surface temperature and application time were evaluated, and a median value of 58 °C and integral value of 1000 °C·s were identified from the receiver operating characteristic curve to be useful effective indicators. However, for LSPV, the PV potential of carina or ridge likely often remained and needed to be independently considered. There was no periprocedural complication including severe pulmonary vein stenosis. During the observation period (median: 280 days, interquartile range: 261-318 days), 17 patients (85%) achieved and maintained sinus rhythm.
Conclusions:
Second-generation HBs with a surface temperature sensor are expected to provide favorable outcomes in AF ablation treatment.
More Related Videos
05:43Author Spotlight: Improving Lesion Contiguity in Pulmonary Vein Isolation via Proactive Esophageal Cooling
Published on: April 19, 2024
04:58Reduced Procedure Time and Variability with Active Esophageal Cooling During Radiofrequency Ablation for Atrial Fibrillation
Published on: August 25, 2022
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...