Related Experiment Video
Updated: Oct 3, 2025

Fabrication and Operation of an Oxygen Insert for Adherent Cellular Cultures
Published on: January 6, 2010
[Automatic Control System of Oxygen Concentration in Medical Hyperbaric Oxygen Chamber Based on ZigBee]
Danna Wang1, Yao Chen2, Huijun Cao3
1First Affiliated Hospital of China Medical University, Shenyang, 110001.
Abstract:
In order to effectively prevent the damage to the human body caused by abnormal oxygen concentration in the medical hyperbaric oxygen chamber, a ZigBee-based medical hyperbaric oxygen chamber oxygen concentration automatic control system is designed. The data acquisition module uses the microprocessor STM32F103C8T6 to receive the oxygen concentration data of each acquisition point, and the ZigBee of the data processing module transmits the processing results to the MSP430G2553 single-chip microcomputer at the receiving end of the slave. The MSP430G2553 single-chip microcomputer uses a self-organizing TS fuzzy neural network (SOTSFNN) and adds activation. The intensity concept realizes automatic control of the oxygen concentration in the hyperbaric oxygen chamber, and controls the buzzer to give an alarm when the oxygen concentration is lower than 19 mg/L and higher than 23 mg/L, and displays the current real-time oxygen concentration through LCD12864. The experimental results show that as the communication distance increases, the packet loss rate of the system is always lower than 5%, and the signal strength under the same communication distance is better; the system can effectively control the oxygen concentration value within the set range, and the oxygen concentration. The control accuracy is high and the stability is good.
Related Concept Videos
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes: