Related Experiment Video
Updated: Oct 3, 2025

03:25
Transcorporal Artificial Urinary Sphincter Cuff Placement in a Case Requiring Revision for Urethral Atrophy
Published on: June 16, 2022
1.0K
Long-term Functional Outcomes and Patient Satisfaction After AdVance and AdVanceXP Male Sling Surgery
Lina Del Favero1, Giovanni Tasso2, Yves Deruyver1
1Department of Urology, University Hospitals Leuven, Leuven, Belgium.
European Urology Focus
|February 13, 2022
Summary
Long-term outcomes for AdVance and AdVanceXP male slings show acceptable continence and satisfaction, but rates decline over time. Patients with prior pelvic radiotherapy or surgeries face higher risks of sling failure.
Area of Science:
- Urology
- Medical Devices
- Patient Outcomes
Background:
- Transobturator male slings, including AdVance and AdVanceXP, are increasingly used for male urinary incontinence.
- Previous studies indicate their safety and efficacy.
Purpose of the Study:
- To assess long-term functional outcomes and patient satisfaction following AdVance or AdVanceXP sling implantation for non-neurogenic male stress urinary incontinence.
- To identify factors predicting poorer outcomes or lower satisfaction.
Main Methods:
- Retrospective analysis of 216 patients who underwent AdVance or AdVanceXP sling surgery (June 2007-April 2018).
- Long-term outcomes and satisfaction were evaluated in 172 patients via standardized questionnaires in April 2020.
- Median follow-up was 49 months.
Main Results:
- At 5 years, overall social continence was 66% (79% in an ideal population).
- Continence rates decreased to 42% at 10 years.
- Patient satisfaction was 71% at 5 years (77% in the ideal population).
- Prior pelvic radiotherapy, incontinence surgery, or urethral stricture surgery were linked to lower continence and satisfaction.
Conclusions:
- AdVance and AdVanceXP slings offer acceptable long-term continence and satisfaction, though these diminish over time.
- Patients with specific prior treatments require careful counseling regarding potential risks for sling failure.