Related Experiment Video
Updated: Oct 3, 2025

Real-Time DC-dynamic Biasing Method for Switching Time Improvement in Severely Underdamped Fringing-field Electrostatic MEMS Actuators
Published on: August 15, 2014
A Semi-Active Control Technique through MR Fluid Dampers for Seismic Protection of Single-Story RC Precast Buildings
Nicola Caterino1,2, Mariacristina Spizzuoco3, Valeria Piccolo1
1Department of Engineering, University of Naples Parthenope, 80100 Naples, Italy.
Abstract:
The work proposes an innovative solution for the reduction of seismic effects on precast reinforced concrete (RC) structures. It is a semi-active control system based on the use of magnetorheological dampers. The special base restraint is remotely and automatically controlled according to a control algorithm, which modifies the dissipative capability of the structure as a function of an instantaneous dynamic response. The aim is that of reducing the base bending moment demand without a significant increase in the top displacement response. A procedure for the optimal calibration of the parameters involved in the control logic is also proposed. Non-linear modelling of a case-study structure has been performed in the OpenSees environment, also involving the specific detailing of a novel variable base restraint. Non-linear time history analyses against natural earthquakes allowed testing of the optimization procedure for the control algorithm parameters, finally the capability of the proposed technology to mitigate seismic risk of new or existing one-story precast RC structures is highlighted.
Related Concept Videos
Posttensioned Masonry Walls
Post-tensioned masonry walls use high-strength steel rods or flexible tendons to enhance the strength and efficiency of masonry structures. These elements are securely anchored to the foundation and extend vertically either within the cores of the masonry units or between the masonry wythes. The construction process involves building the wall with these tensioning elements in place and allowing the mortar to fully cure.
Following the curing process, the tensioning begins. Steel rods are...
Prestressed Concrete
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
Effects of Air-entrainment in Concrete
PD Controller: Design
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...
Design Example: Creating a Hydraulic Model of a Dam Spillway

