Related Experiment Video
Updated: Oct 3, 2025

Evaluation of an Exclusive Spur Dike U-Turn Design with Radar-Collected Data and Simulation
Published on: February 1, 2020
A Vital Signs Fast Detection and Extraction Method of UWB Impulse Radar Based on SVD
Siyun Liu1, Qingjie Qi1, Huifeng Cheng1
1Emergency Research Institute, China Coal Research Institute CCRI, Beijing 100000, China.
Abstract:
The identification of weak vital signs has always been one of the difficulties in the field of life detection. In this paper, a novel vital sign detection and extraction method with high efficiency, high precision, high sensitivity and high signal-to-noise ratio is proposed. Based on the NVA6100 pulse radar system, the radar matrix which contains several radar pulse detection signals is received. According to the characteristics of vital signs and radar matrices, the Singular Value Decomposition (SVD) is adopted to perform signal denoising and decomposition after preprocessing, and the temporal and spatial eigenvectors of each principal component are obtained. Through the energy proportion screening, the Wavelet Transform decomposition and linear trend suppression, relatively pure vital signs in each principal component, are obtained. The human location is detected by the Energy Entropy of spatial eigenvectors, and the respiratory signal and heartbeat signal are restored through a Butterworth Filter and an MTI harmonic canceller. Finally, through an analysis of the performance of the algorithm, it is proved to have the properties of efficiency and accuracy.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation

