Related Experiment Video
Updated: Oct 3, 2025

Selecting Multiple Biomarker Subsets with Similarly Effective Binary Classification Performances
Published on: October 11, 2018
On the Construction of Pareto-Compliant Combined Indicators
J G Falcón-Cardona1, M T M Emmerich2, C A Coello Coello3
1Computer Science Department, CINVESTAV-IPN, Mexico City, 07360, Mexico jfalcon@computacion.cs.cinvestav.mx.
Abstract:
The most relevant property that a quality indicator (QI) is expected to have is Pareto compliance, which means that every time an approximation set strictly dominates another in a Pareto sense, the indicator must reflect this. The hypervolume indicator and its variants are the only unary QIs known to be Pareto-compliant but there are many commonly used weakly Pareto-compliant indicators such as R2, IGD+, and ε+. Currently, an open research area is related to finding new Pareto-compliant indicators whose preferences are different from those of the hypervolume indicator. In this article, we propose a theoretical basis to combine existing weakly Pareto-compliant indicators with at least one being Pareto-compliant, such that the resulting combined indicator is Pareto-compliant as well. Most importantly, we show that the combination of Pareto-compliant QIs with weakly Pareto-compliant indicators leads to indicators that inherit properties of the weakly compliant indicators in terms of optimal point distributions. The consequences of these new combined indicators are threefold: (1) to increase the variety of available Pareto-compliant QIs by correcting weakly Pareto-compliant indicators, (2) to introduce a general framework for the combination of QIs, and (3) to generate new selection mechanisms for multiobjective evolutionary algorithms where it is possible to achieve/adjust desired distributions on the Pareto front.
Related Concept Videos
Pareto Chart
The Pareto chart is named after the Italian economist Vilfredo Pareto, who described the Pareto...
Indicators
Routh-Hurwitz Criterion II
The first scenario occurs when a singular zero appears in the first column of the Routh table. This situation creates a division by zero issues. To resolve this, a small positive or negative number, denoted as epsilon (∈), is substituted for the zero. The stability analysis proceeds by assuming a sign for ∈. If ∈ is positive, any sign change in the first...
Friedman Two-way Analysis of Variance by Ranks
Routh-Hurwitz Criterion I
To apply the Routh-Hurwitz criterion, a Routh table is constructed. The table's rows are labeled with powers of the complex frequency variable s, starting from the...
Central Tendency: Analysis
The mean is one such measure, calculated by totaling all values in a dataset and dividing by the number of values. For instance, the mean blood pressure reading (120, 130, 140, 150) would be 135. However, the mean can be affected by extreme values or outliers.
The median, another measure,...

