Related Experiment Video
Updated: Oct 9, 2026

Combining Single-molecule Manipulation and Imaging for the Study of Protein-DNA Interactions
Published on: August 27, 2014
Cubic DNA nanocage-based three-dimensional molecular beacon for accurate detection of exosomal miRNAs in confined
Dongsheng Mao1, Mengmeng Zheng2, Wenxing Li3
1State Key Laboratory of Functional Material for Informatics, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, PR China; Center for Molecular Recognition and Biosensing, School of Life Sciences, Shanghai University, Shanghai, 200444, PR China.
Abstract:
In situ nondestructive bioanalysis of targets in nanoscale confined space, e.g. exosomes, poses a high challenge to analytical technologies, especially to molecular fluorescent probes, because it is required to enter the confined space to recognize the target, and maintain independent and stable signal output. The unexpected fluorescence quenching and fluorescence resonance energy transfer (FRET) caused by high-frequency Brownian motion and collision in confined space are the main limiting factors. Herein, we constructed a well-defined and programmable cubic DNA nanocage-based three-dimensional molecular beacon (ncMB), which successfully broke through the above dilemma, and realized the detection of miRNA in exosomes. Specifically, steric hindrance and electrostatic repulsion derived from the unique three-dimensional structure of ncMB result in a barrier between fluorescent probes, thus eliminating unexpected fluorescence quenching during single exosomal miRNA detection and unexpected FRET during dual exosomal miRNA detection. Benefiting from the excellent anti-fluorescence and anti-FRET performance of ncMB, compared with traditional molecular beacons (MB), the detected fluorescence signal in exosomes can be improved by an order of magnitude. Moreover, ncMB is proven to have powerful programmability and anti-interference capability. Overall, it is believed that the ncMB can eliminate the signal distortion that was usually associated with commonly used MB, especially in the confined space. The ncMB is considered as a powerful and versatile tool for accurate in situ signal output in exosomes and maybe other confined spaces.
More Related Videos
12:20Real-time Imaging of Single Engineered RNA Transcripts in Living Cells Using Ratiometric Bimolecular Beacons
Published on: August 6, 2014
07:16Author Spotlight: Advancements in DNA Nanosensors – Addressing Sensitivity and Selectivity Challenges in Molecular Detection
Published on: February 9, 2024