Diagnostic Value of the Electroencephalogram and Cerebrospinal Fluid in Viral Encephalitis
Jian-Hua Chen1, Jie Wu2, Xiao-Yan Yang3
1Department of Neurology.
Background:
Electroencephalogram (EEG) and cerebrospinal fluid (CSF) are widely used in the clinical diagnosis of viral encephalitis (VE), but their value in the diagnosis of VE and the detection rate of abnormal indicators need to be further supported by more clinical data.
Methods:
In this study, routine laboratory testing, biochemical examinations of cerebrospinal fluid (CSF) and EEG characteristics were performed in patients with VE to guide the diagnosis and treatment of VE in clinical settings. A total of 330 patients with VE were enrolled in the Department of Neurology of the Third Affiliated Hospital of Zunyi Medical University from January 1, 2015 to January 30, 2020. EEG, routine testing and assessment of biochemical indicators of CSF were performed within 10 days after admission, and the results were analyzed by paired χ 2 test to compare the diagnostic value of EEG and CSF for VE.
Results:
In 330 cases of VE, 283 cases (85.76%) had abnormal EEG, and 189 cases (57.27%) had abnormal CSF indicators. The incidence of EEG abnormalities was higher than that of CSF indicators, and the difference was statistically significant ( P <0.05).
Conclusions:
Both the EEG and CSF analysis are valuable indicators in the diagnosis of VE patients. Compared with the CSF examination, the EEG examination had a better diagnostic efficacy for the diagnosis of VE. In addition, a normal EEG or a normal CSF level cannot exclude VE, and it is still necessary to develop new diagnostic indicators to cover all viral encephalitides.