Purpose:
During computed tomography (CT) examinations, it may be necessary to assist the patient to maintain an appropriate body position. However, there is little protective equipment available for caregivers who approach the gantry. This study aimed to evaluate the effectiveness of novel radiation protective curtains in reducing radiation exposure to caregivers while assisting patients, especially during CT examinations of the head.
Method:
The absorbed dose in air around the gantry during CT examinations of the head was measured using glass dosimeters. The measurement points from the center of the gantry were 40 to 120 cm in the front, 0 to 100 cm for each side in the right and left, and 60 to 180 cm from the floor. Measurements were performed at each 20-cm interval, and all points were accumulated 10 times. The absorbed dose in air in a CT room was compared with and without the protective curtains. Next, we assumed the height of the caregiver to be 170 cm, and measured the points for the crystalline lens, chest, and abdomen. Also, using the protective glasses and the protective apron, we measured the absorbed dose in air for the caregivers behind the protective curtains.
Result:
The absorbed exposure dose in air toward the crystalline lenses, chest, and abdomen was reduced more than 90% by using the protective curtains and more than 95% by using the protective apron and protective glasses in addition to them.
Conclusion:
This study showed the usefulness of protective curtains in reducing the absorbed exposure dose in air to caregivers.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Absorption of Radiation