Biofire FilmArray Meningitis/Encephalitis panel for the aetiological diagnosis of central nervous system infections:

Juliana Trujillo-Gómez1,2,3, Sofia Tsokani4, Catalina Arango-Ferreira1,2

  • 1Department of Paediatrics, Universidad de Antioquia, Calle 67 No. 53-108, Medellín, Antioquia 050001, Colombia.

Eclinicalmedicine
|February 24, 2022
PubMed
Abstract

Insights

The FilmArray Meningitis/Encephalitis (FA/ME) panel shows high accuracy for diagnosing bacterial and viral CNS infections. While generally effective, sensitivities for certain pathogens like Listeria monocytogenes were suboptimal.

Area of Science:

  • Clinical microbiology
  • Infectious diseases
  • Diagnostic test accuracy

Background:

  • The diagnostic test accuracy (DTA) of the FilmArray Meningitis/Encephalitis (FA/ME) panel for central nervous system (CNS) infections requires clarification.
  • The FA/ME panel offers potential benefits in clinical practice.

Purpose of the Study:

  • To determine the DTA of the FA/ME panel for etiological diagnosis in patients with suspected CNS infections.
  • To conduct a systematic review and meta-analysis of existing studies.

Main Methods:

  • Systematic review and DTA meta-analysis (PROSPERO: CRD42020139285).
  • Searched Embase, Medline, and Web of Science until September 2021.
  • Assessed risk of bias using QUADAS-2 and certainty of evidence with GRADE.
  • Included studies comparing FA/ME with reference tests (CSF/blood culture, PCR).
  • Performed random-effects bivariate meta-analysis for sensitivity and specificity.

Main Results:

  • Included 19 studies with 11,351 participants.
  • For bacteria (reference test 1), pooled sensitivity was 89.5% (95% CI 81.1-94.4) and specificity was 97.4% (95% CI 94-98.9).
  • For reference test 2, pooled sensitivity was 92.1% (95% CI 86.8-95.3) and specificity was 99.2% (95% CI 98.3-99.6).
  • For HSV-2, enteroviruses, and VZV, sensitivities ranged from 75.5% to 93.8%, with specificities above 99%.
  • The certainty of the evidence was low.

Conclusions:

  • The FA/ME panel demonstrates acceptable-to-high sensitivity and high specificity for detecting common bacterial and viral pathogens in CNS infections.
  • The panel is particularly accurate for identifying *S. pneumoniae*, HSV-2, and enteroviruses.
  • Suboptimal sensitivities were noted for *L. monocytogenes*, *H. influenzae*, *E. coli*, and HSV-1.