Comparison of [68Ga]-FAPI PET/CT and [18F]-FDG PET/CT in Multiple Myeloma: Clinical Experience
Umut Elboga1, Ertan Sahin1, Yusuf Burak Cayirli1
1Department of Nuclear Medicine, Gaziantep University, Gaziantep 27310, Turkey.
Objective:
In this study, we aimed to compare [68Ga]FAPI PET/CT and [18F]FDG PET/CT imaging to detect lesions in multiple myeloma.
Methods:
A total of 14 patients with multiple myeloma who underwent [68Ga]FAPI PET/CT and [18F]FDG PET/CT imaging were included in this retrospective study. SUVmax values of [68Ga]FAPI and [18F]FDG were compared according to lesion locations. Also, lesion localization ability of both imaging methods was compared on the patient basis.
Results:
In 4 of 14 patients, [68Ga]FAPI PET/CT and [18F]FDG PET/CT have not detected any bone lesions. In 8 of the remaining 10 patients [18F]FDG PET/CT detected bone lesions but in this group, 6 patients showed more higher SUVmax values than [18F]FDG PET/CT in [68Ga]FAPI PET/CT.In contrast, 2 of 8 patients showed more higher SUVmax values than [68Ga]FAPI PET/CT in [18F]FDG PET/CT. Moreover, [68Ga]FAPI PET/CT detected bone lesions in two patients, which werenot detected by [18F]FDG PET/CT. Also, in five patients, [68Ga]FAPI PET/CT showed more bone lesions in comparison with[18F]FDG PET/CT. Only one patient, [18F]FDG PET/CT showed more bone lesions. Three extramedullary involvements were observed in the following locations: lung, presacral lymph node, and soft tissue mass lateral to the right maxillary sinus. Among these involvements, higher SUVmax values were observed in the lung and presacral lymph node with [68Ga]FAPI compared to [18F]FDG. However, the soft tissue mass showed a higher SUVmax value in [18F]FDG than [68Ga]FAPI.
Conclusions:
No significant superiority was observed in [68Ga]FAPI PET/CT over [18F]FDG PET/CT in patients with MM. However, [68Ga]FAPI PET/CT can be utilized as a complementary imaging method to [18F]FDG PET/CT in some settings, especially in low-[18F]FDG affinity and inconclusive cases. Considering the favorable aspects of [68Ga]FAPI PET/CT in MM, such as low background activity, absence of non-specific bone marrow, and physiological brain involvement, further studies with a larger sample size should be conducted.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
![Automated Preparation of [68Ga]Ga-3BP-3940 on a Synthesis Module for PET Imaging of the Tumor Microenvironment](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F68356.jpg&w=3840&q=50)
![An Automated Radiosynthesis of [68Ga]Ga-FAPI-46 for Routine Clinical Use](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F66708.jpg&w=3840&q=50)