Comparative study of photoplethysmographic waveforms with application of antihypertensive medication in hypertensive
Yanchun Hu1, Anming Hu2, Shenju Song3
1Department of Orthopaedics, The Fifth People's Hospital of Jinan, Jinan, China.
Background:
Multiple studies have been published using a pulse oximeter's photoplethysmographic (PPG) capability to detect tissue perfusion. However, the origin of the PPG signal is still debatable.
Aim:
A comparative study was performed of PPG waveforms in hypertensive patients before and after treatment with antihypertensive medication. The aim of this study was to observe the changes of PPG waveforms before and after lowering blood pressure in hypertensive patients and then to detect the relationship between blood pressure and PPG waveforms.
Methods:
The PPG waveforms of 60 patients with hypertension were collected. After administration of the antihypertensive medication nitroglycerin, PPG waveforms were collected again. The changes of the T3 (time3): This phase occurred between Marker 3 and Marker 4 (this phase occurs mid-diastolic) angle, before and after the antihypertensive medication treatment, were compared. The statistical analyses of two related groups were performed using the Paired t-test.
Results:
The blood perfusion waveforms of hypertensive patients before and after antihypertensive medication administration were differently indicated with the tilt angle T3. The slope angle of the T3 phase waveform increased significantly when the blood pressure dropped to normal (-41.9 ± 16.2° vs. -25.6 ± 21.9°, p < .0001), and the tilt angle of some patients was similar to that of adults with normal blood pressure.
Conclusion:
In patients with hypertension, the tilt angle of the PPG waveform in the T3 phase increased significantly after administration of the antihypertensive medication nitroglycerin. It is worth to conduct deeper research about the relationship between hypertension and the blood perfusion of microcirculation in the diastolic period.
Related Concept Videos
Hypertension III: Clinical Manifestations and Diagnostic Studies
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Chronopharmacokinetics: Circadian Rhythms and Influence on Drug Response
The time of drug administration is an important factor to consider, as it can influence the toxic dose of a drug. For example, a study conducted by Prins et al. in 1997 examined the effects of the timing of...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure