Related Experiment Video
Updated: Oct 1, 2025

Free Radicals in Chemical Biology: from Chemical Behavior to Biomarker Development
Published on: April 15, 2013
Supercritical fluid chromatography with post-column addition of supporting electrolyte solution for electrochemical
Kazuhiro Yamamoto1, Takuma Nishimura1, Koichi Machida1
1Department of Analytical Chemistry, School of Pharmacy, Tokyo University of Pharmacy and Life Sciences, Hachioji, Japan.
Abstract:
A supercritical fluid chromatography with electrochemical detection system was developed for the simultaneous determination of tocopherol and tocotrienol isomers. The supercritical fluid chromatography with electrochemical detection system was connected with an additional pump to create a flow path to add a supporting electrolyte solution. The supporting electrolyte solution was mixed with a mobile phase in a post-column fashion, enabling the independent control of the separation and detection. After optimization of the measurement conditions, vitamin E isomers and an internal standard substance (2,2,5,7,8-pentamethyl-6-hydroxychroman) were separated within 30 min using a mixture of supercritical carbon dioxide and methanol (99:1, v/v) as a mobile phase and a cyanopropyl column (4.6 mm inner diameter × 250 mm length, 5 μm). For the electrochemical detection, methanol containing 1.0 mol/L ammonium acetate was used as a supporting electrolyte solution, and the applied potential was set at +0.8 V. This analytical method showed good linearity (5-100 μg/mL) and repeatability (less than 2.5% relative standard deviation, n = 6) and was applicable to the determination of tocopherol and tocotrienol isomers in nutrition supplements.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
11:44Cellular Membrane Affinity Chromatography Columns to Identify Specialized Plant Metabolites Interacting with Immobilized Tropomyosin Kinase Receptor B
Published on: January 19, 2022
Related Concept Videos
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Principles Of Column Chromatography
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Elution Process
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...