Approximately 500,000 dialysis patients in America are at a high risk of hyperkalemia, a condition where blood potassium becomes elevated above normal levels. Hyperkalemia is extremely dangerous, as it can result in severe cardiac complications if untreated. Hyperkalemia may be silent or present vague symptoms until those complications develop, at which point patients require emergency medical care. However, if patients have the ability to measure their potassium levels at home, they could detect hyperkalemia before it reaches a dangerous stage, and seek preventative medical care to avoid severe complications. Therefore, we have designed a novel device allowing patients to measure their blood potassium levels at home. The workflow of our solution is as follows: (1) patients obtain a blood sample from a finger prick, (2) potassium concentration is measured with an ion specific electrode (ISE), and (3) the device displays their potassium levels and a recommended course of action based on their hyperkalemic risk. We validate our solution with three major tests. First, our portable ISE technology must accurately measure potassium concentration in blood samples. Second, appropriate lancet parameters (gauge and depth) to minimize hemolysis in capillary blood samples must be found to minimize falsely elevated readings. Third, device portability and ease of use must be evaluated using patient input, as these factors will affect patient compliance. We have validated the use of portable ISE technology to feasibly measure potassium, and we continue to collect data for our second and third tests.

Related Concept Videos

Hemodialysis I: Introduction01:25

Hemodialysis I: Introduction

Hemodialysis (HD) is a medical treatment that artificially removes waste products, excess fluids, and toxins from the blood when the kidneys are no longer able to perform these functions effectively. In this process, blood is filtered through a semipermeable membrane, allowing for the selective removal of waste while preserving necessary components like blood cells and proteins. Hemodialysis is typically performed in patients with end-stage renal disease (ESRD) or severe kidney...
371
Hemodialysis III: Nursing Management01:25

Hemodialysis III: Nursing Management

The nursing management of a patient undergoing hemodialysis includes several critical steps, starting with a thorough assessment before the procedure.Before the Hemodialysis ProcedureFirst, record the patient's vital signs—blood pressure, heart rate, respiratory rate, and temperature—to establish a baseline. This baseline is essential for detecting conditions such as hypotension that could impact the patient's response to dialysis. Document the patient's pre-dialysis weight, as this...
243
Dialysis01:15

Dialysis

Dialysis is a diffusion-based purification process that separates analyte molecules from a complex matrix. This is accomplished by allowing molecules in the solution to pass through a semipermeable membrane into a liquid on the other side. The membrane is usually made of cellulose acetate or cellulose nitrate, and the second liquid must be miscible with the solution. Ions (e.g., chloride or sodium) or organic molecules (e.g., glucose) can pass through the membrane pores, which generally have...
867
Holter Monitor: 24-Hour Monitoring01:23

Holter Monitor: 24-Hour Monitoring

Holter monitoring is a continuous electrocardiography (ECG) recording that tracks the heart's electrical activity over an extended period, generally 24 to 48 hours. This noninvasive diagnostic tool detects irregular heart rhythms that may not be captured during a standard ECG performed in a clinical setting.DeviceThe Holter monitor is a portable, small device connected to several electrodes on the patient's chest. These electrodes detect the heart's electrical signals and transmit them to the...
403
Acute Kidney Injury V: Interprofessional Care01:20

Acute Kidney Injury V: Interprofessional Care

Acute Kidney Injury (AKI) requires a collaborative healthcare approach to restore renal function and prevent complications. Essential management strategies involve monitoring fluid and electrolyte balance, adjusting medications, initiating dialysis when necessary, and providing nutritional support.Fluid and Electrolyte ManagementFluid Monitoring: Regularly monitoring body weight, central venous pressure, and urine output helps detect fluid imbalances early. Patient intake and output are...
64
Hemodialysis II: Procedure and Complications01:24

Hemodialysis II: Procedure and Complications

DialyzersA hemodialysis (HD) dialyzer is a plastic cartridge containing thousands of parallel hollow fibers, which serve as semipermeable membranes. These fibers are typically made from cellulose-based or other synthetic materials. During HD, blood is pumped into the top of the cartridge and distributed among these fibers. Simultaneously, dialysis fluid, known as dialysate, is introduced into the bottom of the cartridge, bathing the outside of the fibers. Across the semipermeable membrane,...
163