Related Experiment Video
Updated: Oct 1, 2025

11:38
In vivo Imaging of Optic Nerve Fiber Integrity by Contrast-Enhanced MRI in Mice
Published on: July 22, 2014
13.5K
Contrast Sensitivity and Equivalent Intrinsic Noise in X-Linked Retinoschisis
J Jason McAnany1,2, Jason C Park1, Gerald A Fishman1,3
1Department of Ophthalmology and Visual Sciences, University of Illinois at Chicago, Chicago, IL, USA.
Translational Vision Science & Technology
|March 8, 2022
Summary
Internal noise measurements in X-linked retinoschisis (XLRS) reveal a link between elevated noise and reduced contrast sensitivity (CS). Both factors align with a structure-function model, offering insights into vision loss causes.
Area of Science:
- Ophthalmology
- Neuroscience
- Visual Science
Background:
- X-linked retinoschisis (XLRS) is a genetic disorder affecting the retina, leading to vision impairment.
- Contrast sensitivity (CS) is a key measure of visual function, often reduced in retinal diseases.
- Understanding the underlying pathophysiology of vision loss in XLRS is crucial for developing targeted therapies.
Purpose of the Study:
- To investigate the relationship between contrast sensitivity (CS), equivalent intrinsic noise (Neq), and retinal thickness in individuals with XLRS.
- To determine if internal noise contributes to the observed reduction in CS in XLRS patients.
- To assess the correlation between retinal structural measurements and visual function parameters.
Main Methods:
- Contrast sensitivity (CS) was measured in XLRS patients and controls, with and without luminance noise.
- Equivalent intrinsic noise (Neq) and sampling efficiency were estimated using a standard visual model.
- Optical coherence tomography (OCT) was used to measure retinal layer thickness, specifically the outer nuclear layer (ONL+) and outer segment (OS+).
Main Results:
- CS was significantly reduced in XLRS subjects compared to controls.
- A strong negative correlation was found between CS and equivalent intrinsic noise (Neq) in XLRS patients (r = -0.78, P = 0.01).
- Both CS and Neq in XLRS subjects were consistent with predictions from a linear structure-function model incorporating ONL+ and OS+ thickness.
Conclusions:
- Elevated internal noise is a significant factor contributing to reduced contrast sensitivity in some individuals with XLRS.
- The findings support the utility of a structure-function model in understanding visual pathway dysfunction in XLRS.
- Internal noise measurements offer valuable insights into the sources of vision loss in XLRS, potentially guiding future therapeutic strategies.
Related Concept Videos
Photoreceptors and Visual Pathways
6.6K
At the molecular level, visual signals trigger transformations in photopigment molecules, resulting in changes in the photoreceptor cell's membrane potential. The photon's energy level is denoted by its wavelength, with each specific wavelength of visible light associated with a distinct color. The spectral range of visible light, classified as electromagnetic radiation, spans from 380 to 720 nm. Electromagnetic radiation wavelengths exceeding 720 nm fall under the infrared category,...
6.6K
Anatomy of the Eyeball
7.7K
The eye is a spherical, hollow structure composed of three tissue layers. The outer layer — the fibrous tunic, comprises the sclera — a white structure — and the cornea, which is transparent. The sclera encompasses some of the ocular surface, most of which is not visible. However, the 'white of the eye' is distinctively visible in humans compared to other species. The cornea, a clear covering at the front of the eye, enables light penetration. The eye's middle...
7.7K

