Evaluation on the Performance of Hydraulic Bitumen Binders under High and Low Temperatures for Pumped Storage Power
Changgen Zou1, Zhao Hua2, Liantong Mo1
1State Key Laboratory of Silicate Materials for Architectures, Wuhan University of Technology, Wuhan 430070, China.
Abstract:
The high and low-temperature performance of five hydraulic bitumen binders was evaluated using the dynamic shear rheometer (DSR) test, infrared spectrum test and direct tensile (DT) test. These hydraulic bitumen binders were respectively applied for several pumped storage power stations (PSPS) projects that were constructed or under construction. In order to relate the bitumen performance to the mixture performance, the slope flow test, three-point bending test and thermal stress restrained specimen test were carried out on hydraulic asphalt mixtures. The test results indicated the DSR rheological master curves can well distinguish the difference of each bitumen binder as well as the effect of polymer modification. Phase angle master curves, black diagrams and infrared spectra all indicated that several penetration-grade hydraulic bitumen binders were not virgin bitumen binders but were modified with relatively lower SBS polymer content when compared with traditional SBS-modified bitumen. When selecting the commonly used Karamay SG70 hydraulic bitumen as a reference, the normal SBS-modified bitumen was superior to other bitumen in terms of low- and high-temperature performance. Several slightly SBS-modified bitumen binders did not always show consistent results, which indicated that slightly modified bitumen may not really have the desired performance as expected. Therefore, SBS-modified bitumen will be more promising when dealing with extremely low or high temperatures. Bitumen performance was well compared with the mixture performance by using the bitumen creep, relaxation and tensile failure strain corresponding to the asphalt concrete slope flow, the maximum bending strain and the failure temperature, respectively. Compared with the traditional penetration, softening point and ductility test, it indicated that the DSR rheological test, creep test, direct tensile test and stress relaxation test can be used as more powerful tools for the characterization and optimization of hydraulic bitumen binders.
More Related Videos
09:46Protocol for Measuring the Thermal Properties of a Supercooled Synthetic Sand-water-gas-methane Hydrate Sample
Published on: March 21, 2016
12:18Pore-scale Imaging and Characterization of Hydrocarbon Reservoir Rock Wettability at Subsurface Conditions Using X-ray Microtomography
Published on: October 21, 2018
Related Concept Videos
Design Example: Managing Concrete Workability
Hot Weather Concreting
Mitigating the heat increase in concrete can be economically achieved by shading aggregate stockpiles to prevent heating from solar radiation,...
Cold Weather Concreting
To counteract the negative impacts of cold weather, ensuring...
Masonry in Cold and Hot Weather Conditions
Other key practices include keeping masonry units...
Strength and Heat of Hydration
The heat of hydration for each cement compound is significant; for instance, tricalcium aluminate (C3A) and...
Frost Resistant Concrete
Introducing microscopic air bubbles into the concrete mix through air entrainment creates small voids that accommodate ice expansion, thereby reducing internal pressures and preventing cracking. The optimal amount of...