Related Experiment Video
Updated: Sep 30, 2025

A Detailed Protocol for Perspiration Monitoring Using a Novel, Small, Wireless Device
Published on: November 24, 2016
A Low-Cost Sensor Network for Real-Time Thermal Stress Monitoring and Communication in Occupational Contexts
Markus Sulzer1, Andreas Christen1, Andreas Matzarakis1,2
1Chair of Environmental Meteorology, Department of Earth and Environmental Sciences, Faculty of Environment and Natural Resources, University of Freiburg, D-79085 Freiburg, Germany.
Abstract:
The MoBiMet (Mobile Biometeorology System) is a low-cost device for thermal comfort monitoring, designed for long-term deployment in indoor or semi-outdoor occupational contexts. It measures air temperature, humidity, globe temperature, brightness temperature, light intensity, and wind, and is capable of calculating thermal indices (e.g., physiologically equivalent temperature (PET)) on site. It visualizes its data on an integrated display and sends them continuously to a server, where web-based visualizations are available in real-time. Data from many MoBiMets deployed in real occupational settings were used to demonstrate their suitability for large-scale and continued monitoring of thermal comfort in various contexts (industrial, commercial, offices, agricultural). This article describes the design and the performance of the MoBiMet. Alternative methods to determine mean radiant temperature (T) using a light intensity sensor and a contactless infrared thermopile were tested next to a custom-made black globe thermometer. Performance was assessed by comparing the MoBiMet to an independent mid-cost thermal comfort sensor. It was demonstrated that networked MoBiMets can detect differences of thermal comfort at different workplaces within the same building, and between workplaces in different companies in the same city. The MoBiMets can capture spatial and temporal differences of thermal comfort over the diurnal cycle, as demonstrated in offices with different stories and with different solar irradiances in a single high-rise building. The strongest sustained heat stress was recorded at industrial workplaces with heavy machinery.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Thermal Stress
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...