Related Experiment Video
Updated: Sep 30, 2025

Author Spotlight: Assessing the Impact of Novel Iron Chelators on Cancer Cell Metabolism
Published on: February 23, 2024
Application of a luminous intensity variation fluorescent probe for the detection of ferric ions
Abstract:
A luminous intensity variation fluorescent probe (Probe 1) for the detection of ferric ion was developed. The quantitative range of Fe3+ content detected was 0-600 μM with the limit of detection at 0.76 μM. Furthermore, after 20 min of Fe3+ addition, the intensity of the luminescence of Probe 1 solution gradually decreased with increase in Fe3+ concentration. In addition, the B and G values of these images showed a linear relationship with Fe3+ concentration (0-500 μM). Probe 1 was successfully used for the rapid determination of Fe3+ concentration in real samples. This study demonstrates that Probe 1 is an excellent tool for the rapid determination of Fe3+ content in real samples using a smart phone without professional equipment.
Related Concept Videos
Photoluminescence: Applications
Labeling DNA Probes
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...