Graducheck®-a novel device to measure sub-bandage pressures during application of compression
Sylvie Hampton1, Sarah Gray1, Arnold Harpin2
1Tissue Viability Nurse Consultant.
Abstract:
Graduated compression, using bandaging or compression stockings, is the gold-standard treatment for the management of venous leg ulcers (VLUs) and preventing recurrence. However, achieving the required pressures on different parts of the leg is extremely difficult, even for experienced practitioners. Inappropriately applied compression can result in delayed healing and poor compliance. Graducheck® is a pressure sensor system that ensures that the prescribed level of compression is being applied accurately. This study aimed to determine if two experienced tissue viability nurses (TVNs) could achieve accurate pressures using four commonly used bandage systems, as measured using Graducheck sensor strips. Ideal pressures were not achieved, but in two systems, once the application pressure was adjusted according to the sensor level, ideal compression was achieved. In the remaining two systems, ideal pressures could not be produced, even after adjustments to application. Clinically, the Graducheck system could improve the standard of compression therapy, as real-time feedback ensures that corrections can be made. However, further work is required to determine why ideal pressures were not achieved in two of the tested systems.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pressure Gauges
Assessing Blood pressure in the Leg
Preparation:
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...