Related Experiment Video
Updated: Sep 30, 2025

Esophageal Heat Transfer for Patient Temperature Control and Targeted Temperature Management
Published on: November 21, 2017
Continuous monitoring system of gob temperature and its application
Yueping Qin1,2, Linxiao Yan3, Wei Liu4,5
1School of Emergency Management and Safety Engineering, China University of Mining & Technology, Beijing, 100083, People's Republic of China.
Abstract:
Due to the concealment of the fire source in the gob, the fire prevention and extinguishing work in the gob is facing great difficulties. This study is made in order to realize the real-time monitoring of gob temperature and the accurate positioning of high temperature area, so that the fire prevention and extinguishing work in gob can be targeted. In this study, the previously developed COMBUSS-3D software was used to predict the high temperature area in the gob of 85001 working face of Yangmeiwu Coal Mine and II830 working face of Zhuxianzhuang Coal Mine in China, and the continuous monitoring system of gob temperature was independently developed to realize the real-time monitoring of gob temperature, achieving the purpose of accurate positioning of high temperature area in gob. The results show that the high temperature area of the gob of 85001 working face of Yangmeiwu Coal Mine was in the range of approximate circle centered on the point (36.6, 30), and the maximum temperature was 31.7 °C. The high temperature area of the gob of II830 working face in Zhuxianzhuang Coal Mine presented an approximate ellipse centered on (28.2, 25), and the long axis was parallel to the working face, and the maximum temperature was 43.9 °C. The research results are expected to provide reference for the early prediction of spontaneous combustion in gob.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Physical Methods for Controlling Microbial Growth: Temperature
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...