Novel oxygen desaturation parameters are associated with cardiac troponin I: Data from the Akershus Sleep Apnea
Fjola D Sigurdardottir1,2, Caroline Tonje Øverby3,4, Sami Nikkonen5,6
1Department of Cardiology, Akershus University Hospital, Lørenskog, Norway.
Abstract:
Novel diagnostic markers for obstructive sleep apnea beyond the apnea-hypopnea index (AHI) have been introduced. There are no studies on their association with markers of subclinical myocardial injury. We assessed the association between novel desaturation parameters and elevated cardiac troponin I and T. Participants with polysomnography (498) from the Akershus Sleep Apnea study were divided into normal and elevated biomarker groups based on sex-specific concentration thresholds (cardiac troponin I: ≥4 ng/L for women, ≥6 ng/L for men; and cardiac troponin T: ≥7 ng/L for women, ≥8 ng/L for men). Severity of obstructive sleep apnea was evaluated with the AHI, oxygen desaturation index, total sleep time with oxygen saturation below 90% (T90), lowest oxygen saturation (Min SpO2 %), and novel oxygen desaturation parameters: desaturation duration and desaturation severity. How the AHI and novel desaturation parameters predicted elevated cardiac troponin I and cardiac troponin T levels was assessed by the area under the curve (AUC). Based on multivariable-adjusted linear regression, the AHI (β = 0.004, p = 0.012), desaturation duration (β = 0.007, p = 0.004), and desaturation severity (β = 0.147, p = 0.002) were associated with cardiac troponin I levels but not cardiac troponin T. T90 was associated with cardiac troponin I (β = 0.006, p = 0.009) and cardiac troponin T (β = 0.005, p = 0.007). The AUC for the AHI 0.592 (standard error 0.043) was not significantly different from the AUC of T90 (SD 0.640, p = 0.08), desaturation duration 0.609 (SD 0.044, p = 0.42) or desaturation severity 0.616 (SD 0.043, p = 0.26) in predicting myocardial injury as assessed by cardiac troponin I. Oxygen desaturation parameters and the AHI were associated with cardiac troponin I levels but not cardiac troponin T levels. Novel oxygen desaturation parameters did not improve the prediction of subclinical myocardial injury compared to the AHI.
More Related Videos
04:20Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
08:35Oxygenation-sensitive Cardiac MRI with Vasoactive Breathing Maneuvers for the Non-invasive Assessment of Coronary Microvascular Dysfunction
Published on: August 17, 2022
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Acute Coronary Syndrome III: Diagnostic Studies
Sleep Apnea
The condition is more prevalent among...
Acute Coronary Syndrome I: Introduction
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...