Related Experiment Video
Updated: Sep 30, 2025

Calculating Heart Rate Variability from ECG Data from Youth with Cerebral Palsy During Active Video Game Sessions
Published on: June 5, 2019
Reliability of Symbolic Analysis of Heart Rate Variability and Its Changes During Sympathetic Stimulation in Elite
Jakub S Gąsior1, Maciej Rosoł2, Marcel Młyńczak2
1Department of Pediatric Cardiology and General Pediatrics, Medical University of Warsaw, Warsaw, Poland.
Background And Purpose:
Most studies on heart rate variability (HRV) in professional athletes concerned linear, time-, and frequency-domain indices, and there is lack of studies on non-linear parameters in this group. The study aimed to determine the inter-day reliability, and group-related and individual changes of short-term symbolic dynamics (SymDyn) measures during sympathetic nervous system activity (SNSa) stimulation among elite modern pentathletes.
Methods:
Short-term electrocardiographic recordings were performed in stable measurement conditions with a 7-day interval between tests. SNSa stimulation via isometric handgrip strength test was conducted on the second day of study. The occurrence rate of patterns without variations (0V), with one variation (1V), two like (2LV), and two unlike variations (2UV) obtained using three approaches (the Max-min, the σ, and the Equal-probability methods) were analyzed. Relative and absolute reliability were evaluated.
Results:
All SymDyn indices obtained using the Max-min method, 0V, and 2UV obtained using the σ method, 2UV obtained using the Equal-probability method presented acceptable inter-day reliability (the intraclass correlation coefficient between .91 and .99, Cohen's d between -.08 and .10, the within-subject coefficient of variation between 4% and 22%). 2LV, 2UV, and 0V obtained using the Max-min and σ methods significantly decreased and increased, respectively, during SNSa stimulation-such changes were noted for all athletes. There was no significant association between differences in SymDyn parameters and respiratory rate in stable conditions and while comparing stable conditions and SNSa stimulation.
Conclusion:
SymDyn indices may be used as reliable non-respiratory-associated parameters in laboratory settings to detect autonomic nervous system (ANS) activity modulations in elite endurance athletes. These findings provide a potential solution for addressing the confounding influence of respiration frequency on HRV-derived inferences of cardiac autonomic function. For this reason, SymDyn may prove to be preferable for field-based monitoring where measurements are unsupervised.
More Related Videos
06:24Examining Changes in HRV and Emotion Following Artmaking with Three Different Art Materials
Published on: January 11, 2020
05:48Autonomic Function Following Concussion in Youth Athletes: An Exploration of Heart Rate Variability Using 24-hour Recording Methodology
Published on: September 21, 2018
Related Concept Videos
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Regulation of Heart Rates
The SNS increases heart rate through the release of norepinephrine and epinephrine, which act on beta-1 adrenergic receptors in the heart. This action increases the rate of depolarization in the sinoatrial (SA) node, the heart's...
Regulation of Pulse
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...