A Clinical Trial Assessing the Safety, Efficacy, and Delivery of Olive-Oil-Based Three-Chamber Bags for Parenteral Nutrition
Published on: September 20, 2019
Patients' Perception of the Use of the EasyPod™ Growth Hormone Injector Device and Impact on Injection Adherence: A
Asma Deeb1, Saif Al Yaarubi2, Bassam Bin Abbas3
1Sheikh Shahbout Medical City & Khalifa University, Abu Dhabi, United Arab Emirates.
Objective:
This study aimed to assess patient perceptions of the use of the EasyPod™ growth hormone delivery device and its association with compliance.
Methods:
This cross-sectional, multicenter study was conducted in six centers from three countries (United Arab Emirates, Oman, and Saudi Arabia,) between March 2020 and June 2020. Children and adolescents aged 3-18 years, diagnosed with growth disorders and receiving rhGH through the EasyPod™ device were enrolled. Patients and caregivers were given a pre-set questionnaire that evaluated patient satisfaction, preference for technical and personalized features, and device drawbacks. The results were analyzed using independent measures of analysis of variance to evaluate the association of higher satisfaction with device features and better compliance.
Results:
A total of 186 patients were enrolled in the study. Of these, 45.7% had GH deficiency. The mean age (±SD) of patients was 11.8 (±2.76) years; 117 (62.90%) were males. Average compliance was 87%. One hundred patients (53.76%) had injection compliance of ≥90%. Amongst these patients, 74%, 68%, and 77% top-scored (5/5) the technical features of hidden needle, skin sensor, and pre-set dosing, respectively, compared to top scores by 39%, 34%, and 51% patients in the <90% compliance group (p-value <0.05). Similarly, a statistically significant difference was observed between the groups (p-value <0.05) in the perception of the usefulness of the tracking features such as display of history of injected doses (78% vs. 47.7%), a reminder for medicine remaining (46% vs. 23.3%) and battery power indicator (48% vs. 20.9%). Personal screen messages were associated with higher compliance while the requirement to keep the device in the fridge was reported as the most inconvenient feature by 56% of patients in the higher compliance group as against 39.5% in the lower compliance group (p-value <0.05). There was no statistically significant difference in the intensity of pain reported in the two compliance groups.
Conclusion:
Our study showed that there is a statistically significant association between better perception of device features and higher compliance.
Related Concept Videos
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
The Placebo Effect
Drug Delivery: Parenteral Route
There are three primary parenteral routes: intravenous (IV), intramuscular (IM), and subcutaneous (SC). The IV route introduces the drug directly into the bloodstream, ensuring immediate action. The IM route...
Insulin Formulations: Types and Delivery
Short-acting insulins are divided into...
Factors Affecting Protein-Drug Binding: Patient-Related Factors
Age stands as a key determinant in protein-drug binding. Neonates, characterized by low albumin content, experience heightened concentrations of unbound drugs such as phenytoin and...
Drug Delivery: Miscellaneous Routes
Oral inhalation and nasal sprays swiftly transfer drugs across the respiratory epithelium's mucosal layer. Inhaled glucocorticoids and bronchodilators directly target lung conditions such as asthma, while fluticasone nasal spray mitigates allergic rhinitis.
Transdermal patches transport drugs...