Rasch Analysis of the International Quality of Life Basic Data Set Version 2.0
Marcel W M Post1, Carolina S Fellinghauer2, Susan Charlifue3
1Center of Excellence for Rehabilitation Medicine, UMC Utrecht Brain Center, University Medical Center Utrecht and De Hoogstraat Rehabilitation, Utrecht, the Netherlands; University of Groningen, University Medical Center Groningen, Department of Rehabilitation Medicine, Groningen, the Netherlands.
Objective:
To examine the internal construct validity of the International Spinal Cord Injury Quality of Life Basic Data Set Version 2.0 (QoL-BDS V2.0) and compare this with the internal construct validity of the original version of the QoL-BDS.
Design:
International cross-sectional psychometric study.
Setting:
Spinal rehabilitation units, clinics, and community.
Participants:
The study involved 5 sites and 4 countries, 2 of whose primary language is not English. Each site included a consecutive sample of inpatients with spinal cord injury or disease (SCI/D) and a convenience sample of individuals with SCI/D living in the community (N=565).
Main Outcome Measures:
The QoL-BDS V2.0 consists of the 3 original items on satisfaction with life as a whole, physical health, psychological health of the QoL-BDS, and an additional item on satisfaction with social life. All 4 items are answered on a 0-10 numeric rating scale. Rasch analysis was performed on versions 1.0 and 2.0 of the QoL-BDS to examine the ordering of the items' response options, item scaling, reliability, item fit, local item independence, differential item functioning, and unidimensionality.
Results:
The sample included 565 participants with 57% outpatients and 43% inpatients. Mean age was 51.4 years; 71% were male; 65% had a traumatic injury, 40% had tetraplegia, and 67% were wheelchair users. Item thresholds were collapsed for ordering, and subsequent analyses showed good internal construct validity for the QoL-BDS V2.0 with a person separation reliability of 0.76 and Cronbach α of 0.81. Infit and outfit statistics ranged 0.62-0.91. No local dependencies and multidimensionality were found. Differential item functioning was observed only for country and inpatients vs outpatients but not for other participants' characteristics. Differences in internal construct validity between the 3-item and 4-item versions were minimal.
Conclusions:
The results of this Rasch analysis support the internal construct validity of the QoL-BDS V2.0.
Related Concept Videos
Ratio Level of Measurement
A set of data measured using the ratio scale takes care of the ratio problem and provides complete information. Ratio scale data are like interval scale data, except they have a zero point and ratios can be calculated....
Statistical Methods for Analyzing Epidemiological Data
Statistical Package for the Social Sciences (SPSS)
SPSS streamlines the process from data preparation to analysis and reporting. It is characterized by its user-friendly interface, which conceals...
Qualitative Analysis
There are two main approaches to qualitative analysis:...
Friedman Two-way Analysis of Variance by Ranks
Ordinal Level of Measurement
Data measured using an ordinal scale are similar to nominal scale data, but there is one major difference. The ordinal scale data can be ordered. An example of ordinal scale data is a list of the top five national parks...