Related Experiment Video
Updated: Sep 29, 2025

Roughness Impact of Piezoelectric Dental Scaler on Two Distinct Flowable Composite Filling Materials
Published on: January 10, 2025
In Vitro Qualitative Evaluation of Root-End Preparation Performed by Piezoelectric Instruments
Calogero Bugea1, Federico Berton2, Antonio Rapani2
1Independent Researcher, 73100 Lecce, Italy.
Abstract:
Although the application of ultrasounds in endodontic surgery allows for effective debridement of the root canal, incorrect device setting or inefficient tips seem to generate cracks during root-end retropreparation. The primary aim of this in vitro study was to establish the presence, or absence, of a correlation between ultrasonic root-end preparation and the formation of cracks. The present study was conducted on human teeth, extracted for periodontal reasons. After root canal treatment, roots were resected 3 mm from the anatomical apex by using a high-speed handpiece and carbide burs. The resected teeth were retroprepared by using an ultrasonic tip (R1D, Piezomed, W&H, Bürmoos, Austria), setting the piezoelectric device at maximum power available for the tip. Time required for the retropreparation was recorded. Before and after retropreparation, all roots were photographed under a stereomicroscope and analyzed by two different operators to evaluate: (a) the presence and extension of dentinal cracks and (b) the morphology of root-end preparation. Finally, piezoelectric tips were analyzed by scanning electron microscopy (SEM) to evaluate morphologic changes after use. A total of 43 single roots (33 with one root canal, 10 with two root canals) were treated. Average preparation time was 1 minute and 54 seconds. None of the roots without initial cracks developed new cracks after retropreparation. Quality of the preparation margins was fairly equal among the prepared specimens. None of the piezoelectric tips broke during instrumentation, and SEM analysis showed minimal surface wear of the tips after performing 11 retropreparations. Within the limits of the present study, the tested piezoelectric system does not seem to represent a major cause for root crack formation. Pre-existing cracks may expand after ultrasound root-end preparation.
More Related Videos
07:44Characterization of Full Set Material Constants and Their Temperature Dependence for Piezoelectric Materials Using Resonant Ultrasound Spectroscopy
Published on: April 27, 2016
06:09Piezo High Accuracy Surgical Osteal Removal PHASOR: A Technique for Improved Cranial Window Surgery in Mice
Published on: March 2, 2018