Related Experiment Video
Updated: Aug 14, 2026

Fabrication of Electrochemical-DNA Biosensors for the Reagentless Detection of Nucleic Acids, Proteins and Small Molecules
Published on: June 1, 2011
Metal-organic framework nanoreactor-based electrochemical biosensor coupled with three-dimensional DNA walker for
Lingyi Kong1, Shuzhen Lv1, Zhenjie Qiao1
1College of Chemistry and Chemical Engineering, Qingdao University, Qingdao, 266071, PR China.
Abstract:
MicroRNAs (miRNAs), serving as the regulators for gene expression and cellular function, have emerged as the important biomarkers for diagnosis of cancers. In this study, a label-free electrochemical biosensing platform equipped with metal-organic frameworks (MOFs)-based nanoreactors has been developed by coupling three-dimensional (3D) DNA walker for amplification detection of miRNA. The MOF-based nanoreactors are constructed via the encapsulation of GOx in zeolitic imidazolate framework-8 (ZIF-8) driven by the rapid GOx-triggered nucleation of ZIF-8 with high catalytic activity, which also contributes to preserve the biological activity of GOx even in harsh environments. The gold nanoparticles (AuNPs) are further loaded on the surface of ZIF-8 by electrostatic adsorption, which can be used to not only anchor the orbit of 3D DNA walker by Au-S covalent bond but also promote the electron transfer on electrode interface. In the presence of target miRNA-21, the 3D DNA walker is initiated, resulting in the recycling of targets and the immobilization of numerous fuel DNAs with G-quadruplex/hemin complex on the nanoreactors spontaneously. As a result, a cascade catalysis reaction is triggered in the confined space of ZIF-8 nanoreactors, where the H2O2 as an intermediate is generated with the oxidization of glucose catalyzed by GOx and subsequently decomposed by G-quadruplex/hemin HRP-mimicking DNAzyme for the further oxidation of ABTS to obtain a differential pulse voltammetry (DPV) signal. Under the optimal conditions, the proposed electrochemical biosensor exhibits an excellent performance for amplification detection of miRNA-21 in the dynamic working range from 0.1 nM to 10 μM with a detection limit of 29 pM, which opens a new way for clinical analysis of miRNAs and early diagnosis of cancers.
More Related Videos
14:53A Microfluidic-based Electrochemical Biochip for Label-free DNA Hybridization Analysis
Published on: September 10, 2014
13:42Dry Film Photoresist-based Electrochemical Microfluidic Biosensor Platform: Device Fabrication, On-chip Assay Preparation, and System Operation
Published on: September 19, 2017