Estimation of critical closing pressure using intravascular blood pressure of the common carotid artery
Related Experiment Video
Updated: Sep 28, 2025

Analysis of Cerebral Vasospasm in a Murine Model of Subarachnoid Hemorrhage with High Frequency Transcranial Duplex Ultrasound
Published on: June 3, 2021
Yunyun Liang1, Pei Mo2, Xinguang Yang3
1Department of Rehabilitation Medicine, the Second Affiliated Hospital of Guangzhou Medical University, Guangzhou, China.
Purpose:
Radial artery, femoral artery, and aortic arterial blood pressures (ABPs) can be used to estimate cerebral critical closing pressure (CrCP) and resistance-area product (RAP). However, the use of the common carotid artery (CCA) intravascular blood pressure to estimate CrCP is unclear. Thus, using continuous ABP monitoring, we compared the CrCP and RAP estimated from CCA measurements with the corresponding values acquired from the radial artery.
Methods:
In this retrospective cross-sectional study, we analyzed CrCP and RAP estimations from 21 patients with normal cerebral blood vessels between July 23, 2010, and February 9, 2011, using linear regression of the cerebral blood flow velocity-ABP relationship.
Results:
Bland-Altman analysis showed that the average differences (95% limits of agreement) between the radial artery and the left CCA were -6.3 (-53.1 - 40.6) mmHg and -0.08 (-0.41 - 0.25) mmHg s cm-1 for CrCP and RAP, respectively.
Conclusions:
The CrCP and RAP estimated from the CCA measurements are consistent with the corresponding values obtained from the radial artery.
More Related Videos
09:36A Magnetic Resonance Imaging-based Computational Protocol for Analysis of Plaque Morphology and Hemodynamics in Patients with Carotid Artery Stenosis
Published on: August 12, 2025
07:38Cardiac Catheterization in Mice to Measure the Pressure Volume Relationship: Investigating the Bowditch Effect
Published on: June 14, 2015
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...