Related Experiment Video
Updated: Sep 28, 2025

Lung CT Segmentation to Identify Consolidations and Ground Glass Areas for Quantitative Assesment of SARS-CoV Pneumonia
Published on: December 19, 2020
Diagnostic performance of CO-RADS for COVID-19: a systematic review and meta-analysis
Guina Liu1,2, Yuntian Chen3, A Runa4
1Department of Ophthalmology, West China Hospital, Sichuan University, Chengdu, Sichuan, People's Republic of China.
Objectives:
To investigate the diagnostic performance of the coronavirus disease 2019 (COVID-19) Reporting and Data System (CO-RADS) for detecting COVID-19.
Methods:
We searched PubMed, EMBASE, MEDLINE, Web of Science, Cochrane Library, and Scopus database until September 21, 2021. Statistical analysis included data pooling, forest plot construction, heterogeneity testing, meta-regression, and subgroup analyses.
Results:
We included 24 studies with 8382 patients. The pooled sensitivity and specificity and the area under the curve (AUC) of CO-RADS ≥ 3 for detecting COVID-19 were 0.89 (95% confidence interval (CI) 0.85-0.93), 0.68 (95% CI 0.60-0.75), and 0.87 (95% CI 0.84-0.90), respectively. The pooled sensitivity and specificity and AUC of CO-RADS ≥ 4 were 0.83 (95% CI 0.79-0.87), 0.84 (95% CI 0.78-0.88), and 0.90 (95% CI 0.87-0.92), respectively. Cochran's Q test (p < 0.01) and Higgins I2 heterogeneity index revealed considerable heterogeneity. Studies with both symptomatic and asymptomatic patients had higher specificity than those with only symptomatic patients using CO-RADS ≥ 3 and CO-RADS ≥ 4. Using CO-RADS ≥ 4, studies with participants aged < 60 years had higher sensitivity (0.88 vs. 0.80, p = 0.02) and lower specificity (0.77 vs. 0.87, p = 0.01) than studies with participants aged > 60 years.
Conclusions:
CO-RADS has favorable performance in detecting COVID-19. CO-RADS ≥ 3/4 might be applied as cutoff values given their high sensitivity and specificity. However, there is a need for more well-designed studies on CO-RADS.
Key Points:
• CO-RADS shows a favorable performance in detecting COVID-19. • CO-RADS ≥ 3 had a high sensitivity 0.89 (95% CI 0.85-0.93), and it may prove advantageous in screening the potentially infected people to prevent the spread of COVID-19. • CO-RADS ≥ 4 had high specificity 0.84 (95% CI 0.78-0.88) and may be more suitable for definite diagnosis of COVID-19.
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Receiver Operating Characteristic Plot
Acute Coronary Syndrome III: Diagnostic Studies
Rheumatic Heart Disease II: Clinical Manifestations and Diagnostic Studies
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...

