3D CAIPIRINHA SPACE versus standard 2D TSE for routine knee MRI: a large-scale interchangeability study
Pieter Van Dyck1,2, Céline Smekens3, Ella Roelant4
1Department of Radiology, Antwerp University Hospital (UZA), Drie Eikenstraat 655, B-2650, Edegem, Belgium. pieter.van.dyck@uza.be.
Three-dimensional (3D) controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) sampling perfection with application optimized contrast using different flip angle evolutions (SPACE) TSE knee MRI is interchangeable with standard 2D TSE for most diagnoses. This accelerated 3D technique is justified for routine practice despite a slight preference for 2D imaging.
Area of Science:
- Radiology and Medical Imaging
- Orthopedic MRI
- Advanced MRI Techniques
Background:
- Standard 2D TSE protocols are time-consuming for knee MRI.
- 3D CAIPIRINHA SPACE TSE offers potential for accelerated knee imaging.
- Assessing the diagnostic interchangeability of 3D CAIPIRINHA SPACE TSE with standard 2D TSE is crucial for clinical adoption.
Purpose of the Study:
- To compare the diagnostic performance and interchangeability of 3D CAIPIRINHA SPACE TSE with standard 2D TSE for knee MRI.
- To evaluate image quality, diagnostic confidence, and accuracy in identifying knee pathologies between the two MRI protocols.
Main Methods:
- Prospective study of 250 patients undergoing 3T knee MRI with both 3D CAIPIRINHA SPACE TSE (9:26 min) and standard 2D TSE (12:14 min) protocols.
- Two radiologists assessed image quality and diagnosed meniscal, ligamentous, and cartilaginous abnormalities using a 4-point Likert scale.
- Interchangeability, interreader reliability, and intermethod concordance were statistically evaluated.
Main Results:
- Protocols were interchangeable for most knee abnormalities, with exceptions for patellar and trochlear cartilage defects.
- Standard 2D TSE demonstrated higher image quality and diagnostic confidence compared to 3D CAIPIRINHA SPACE TSE.
- Interreader reliability and intermethod concordance were substantial to almost perfect for both protocols.
Conclusions:
- Multicontrast 3D CAIPIRINHA SPACE TSE is diagnostically interchangeable with standard 2D TSE for knee abnormalities, excluding patellofemoral cartilage defects.
- Despite a radiologist preference for 2D TSE, the time-saving 3D CAIPIRINHA SPACE TSE protocol is justified for routine knee MRI.
- Further optimization of 3D TSE techniques may enhance diagnostic confidence and image quality for cartilage assessment.
More Related Videos
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
09:41A Pipeline for 3D Multimodality Image Integration and Computer-assisted Planning in Epilepsy Surgery
Published on: May 20, 2016
Related Concept Videos
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies IV: Magnetic Resonance Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...