A new digital single-axis fluxgate magnetometer according to the cobalt-based amorphous effects
Ruiping Yang1, Hongpeng Wang1, Huan Liu1
1School of Automation, China University of Geosciences, Wuhan 430074, China.
Abstract:
Fluxgate sensors are currently widely used for weak magnetic field measurement because of their relatively great performance, such as resolution, power consumption, and measurement of vector magnetic fields directly. Since the analog fluxgate sensor has some drawbacks, e.g., it would be influenced by the noise of the analog circuit. Hence, in recent years, the analog circuit is gradually inclined to be realized by digital processing in which the software parameter adjustment is employed to replace the analog components, which can greatly improve the flexibility of the design. This paper proposes a digital single-axis fluxgate sensor according to the cobalt-based amorphous effect. To be specific, the analog signal output by the fluxgate is sampled directly by an analog-to-digital converter to obtain the signal waveform in digital form after amplification. The demodulation, filtering, and integration of the signal are all solved by mathematical algorithms. Based on the working principle of the fluxgate sensor, the selection of the magnetic core material and coil winding method of the fluxgate sensor probe is introduced in detail. The design and function of the excitation circuit and preamplifier circuit, as well as the specific realization of digital signal processing, are described. Finally, the performance test of the digital fluxgate sensor was performed under laboratory conditions, and the magnetic anomaly detection comparison experiment was performed outdoors with commercial fluxgate sensors. To sum up, the linearity of the digital single-axis fluxgate sensor is better than 1 × 10-5, and the root mean square noise value is below 0.1 nT. At the same time, it has good magnetic field tracking performance and is extremely sensitive to the magnetic field of the measurement area.
Related Concept Videos
Magnetic Flux
Suppose a surface is divided into elements of area dA. For each element, the component of the magnetic field that is normal to the...
Magnetic Susceptibility and Permeability
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
Diamagnetism
Diamagnetism was discovered by Anton Brugmans in 1778 when he observed that bismuth gets repelled by magnetic fields, thus theorizing that diamagnets get repelled by magnets....
Galvanometer
The galvanometer consists of two concave-shaped permanent magnets, providing a uniform radial magnetic field in the annular region. In the center, a pivoted coil of fine copper wire is placed in the uniform...
Ferromagnetism
Magnetic Field Of A Current Loop