Related Experiment Video
Updated: Sep 28, 2025

Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments
Published on: January 20, 2022
Separation of isomers using a differential mobility analyser (DMA): Comparison of experimental vs modelled ion
A Bianco1, I Neefjes1, D Alfaouri1
1Institute for Atmospheric and Earth System Research/Physics, Faculty of Science, University of Helsinki, FI-00014, Finland.
Abstract:
Mass spectrometry is uniquely suited to identify and quantify environmentally relevant molecules and molecular clusters. Mass spectrometry alone is, however, not able to distinguish between isomers. In this study, we demonstrate the use of both an experimental set-up using a differential mobility analyser, and computational ion mobility calculations for identification of isomers. In the experimental set-up, we combined electrospray ionisation with a differential mobility analyser time-of-flight mass spectrometer to separate environmentally relevant constitutional isomers, such as catechol, resorcinol and hydroquinone, and configurational isomers, such as cyclohexanediols and fatty acids (i.e., oleic and elaidic acids). Computational ion mobility predictions were obtained using the Ion Mobility Software (IMoS) program. We find that isomer separation can be achieved with the differential mobility analyser, while for catechol, resorcinol and hydroquinone, the computational predictions can reproduce the experimental order of the ion mobilities between the isomers, confirming the isomer identification. Our experimental set-up allows analysis both in the gas and liquid phase. The differential mobility analyser can, moreover, be combined with any mass spectrometry set-up, making it a versatile tool for the separation of isomers.
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
10:41Ion Exchange Chromatography IEX Coupled to Multi-angle Light Scattering MALS for Protein Separation and Characterization
Published on: April 5, 2019
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Ion-Exchange Chromatography
Analyte Adsorption and Distribution
High-Resolution Mass Spectrometry (HRMS)
Chemical Ionization (CI) Mass Spectrometry
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...