CT detects more osteoporotic endplate depressions than radiograph: a descriptive comparison of 76 vertebrae
E-Z Du1, Y X J Wáng2
1Department of Radiology, Dongguan Traditional Chinese Medicine Hospital, Dongguan, Guangdong province, China.
Abstract:
This study analyzed elderly women who had chest radiograph and chest CT with indications other than spine disorders. Using CT images as reference, the study demonstrates that radiograph can miss a high portion of mild endplate depression. Detection of endplate depression is confounded by the limitation of projectional overlay for radiograph.
Introduction:
The definition of radiographic OVF (osteoporotic vertebral fracture) remains controversial. Some authors suggest all OVFs should demonstrate endplate fracture/depression on radiograph. Using CT image as the reference, our study tests the hypothesis that a considerable portion of endplate depressions not seen on radiograph can be detected on CT.
Methods:
We retrospectively analyzed 46 female cases (age: 67-94 years) who had both chest radiography and chest CT with indications other than spine disorders. Sixty-six "vertebrae of interest" were identified on radiograph; then, CT images were read side-by-side with lateral chest radiograph.
Results:
Thirty-eight vertebrae (38/66) had anterior wedging deformity with height loss of < 20% while without radiographic endplate depression. Among them, 28 vertebrae had endplate depression and 8 vertebrae had no endplate depression on CT, while 2 vertebrae with "very" minimal deformity were read as normal on CT. In 9 vertebrae (9/66) with anterior wedging and height loss of ≥ 20%, all had additional endplate depression seen on CT. Five vertebrae (5/66) had ambiguous endplate depression on radiograph, 3 had endplate depression on CT while the other 2 vertebrae in one patient were false positive due to X-ray projection. There were 14 short height vertebrae (14/66) where middle and anterior heights were reduced to the same extent while did not show apparent anterior wedging or bi-concaving. Four cases each had one short height vertebra, and all had endplate depression on CT. Another 4 cases had 2, 2, 3, and 3 adjacent short height vertebrae, respectively, and all did not show endplate depression on CT. In addition, inspection of spine CT showed 10 vertebrae in 9 cases appeared normal on radiograph while demonstrated endplate depression on CT.
Conclusion:
With CT images as reference, radiograph can miss a high portion of mild endplate depressions.