Related Experiment Video
Updated: Sep 28, 2025

Evaluation of an Exclusive Spur Dike U-Turn Design with Radar-Collected Data and Simulation
Published on: February 1, 2020
Improving on the Adrogué-Madias Formula
Sheldon Chen1, Michael Shieh2, Robert Chiaramonte3
1Section of Nephrology, MD Anderson Cancer Center, Houston, Texas.
Abstract:
The Adrogué-Madias (A-M) formula is correct as written, but technically, it only works when adding 1 L of an intravenous (IV) fluid. For all other volumes, the A-M algorithm gives an approximate answer, one that diverges further from the truth as the IV volume is increased. If 1 L of an IV fluid is calculated to change the serum sodium by some amount, then it was long assumed that giving a fraction of the liter would change the serum sodium by a proportional amount. We challenged that assumption and now prove that the A-M change in [sodium] ([Na]) is not scalable in a linear way. Rather, the Δ[Na] needs to be scaled in a way that accounts for the actual volume of IV fluid being given. This is accomplished by our improved version of the A-M formula in a mathematically rigorous way. Our equation accepts any IV fluid volume, eliminates the illogical infinities, and most importantly, incorporates the scaling step so that it cannot be forgotten. However, the nonlinear scaling makes it harder to obtain a desired Δ[Na]. Therefore, we reversed the equation so that clinicians can enter the desired Δ[Na], keeping the rate of sodium correction safe, and then get an answer in terms of the volume of IV fluid to infuse. The improved equation can also unify the A-M formula with the corollary A-M loss equation wherein 1 L of urine is lost. The method is to treat loss as a negative volume. Because the new equation is just as straightforward as the original formula, we believe that the improved form of A-M is ready for immediate use, alongside frequent [Na] monitoring.
More Related Videos
14:55Evaluating the Effect of Roadside Parking on a Dual-Direction Urban Street
Published on: January 20, 2023
09:00Indoor Experimental Assessment of the Efficiency and Irradiance Spot of the Achromatic Doublet on Glass ADG Fresnel Lens for Concentrating Photovoltaics
Published on: October 27, 2017
Related Concept Videos
Routh-Hurwitz Criterion II
The first scenario occurs when a singular zero appears in the first column of the Routh table. This situation creates a division by zero issues. To resolve this, a small positive or negative number, denoted as epsilon (∈), is substituted for the zero. The stability analysis proceeds by assuming a sign for ∈. If ∈ is positive, any sign change in the first...
Area Computation by the Alternative Coordinate Method
Routh-Hurwitz Criterion I
To apply the Routh-Hurwitz criterion, a Routh table is constructed. The table's rows are labeled with powers of the complex frequency variable s, starting from the...
Bernoulli's Equation: Problem Solving
The first step is to compute the cross-sectional areas of the pipe and the Venturi throat to analyze the pressure difference indicated by the pressure gauge. Next, the continuity...
Distance Corrections
Clausius-Clapeyron Equation