Improving on the Adrogué-Madias Formula

Sheldon Chen1, Michael Shieh2, Robert Chiaramonte3

  • 1Section of Nephrology, MD Anderson Cancer Center, Houston, Texas.

Kidney360
|April 4, 2022
PubMed
Summary

The Adrogué-Madias formula for serum sodium correction is only accurate for 1 L of fluid. An improved, nonlinear formula accurately calculates sodium changes for any intravenous fluid volume, enhancing clinical precision.

Related Concept Videos

Routh-Hurwitz Criterion II01:19

Routh-Hurwitz Criterion II

In the application of the Routh-Hurwitz criterion, two specific scenarios can arise that complicate stability analysis.
The first scenario occurs when a singular zero appears in the first column of the Routh table. This situation creates a division by zero issues. To resolve this, a small positive or negative number, denoted as epsilon (∈), is substituted for the zero. The stability analysis proceeds by assuming a sign for ∈. If ∈ is positive, any sign change in the first...
448
Area Computation by the Alternative Coordinate Method01:24

Area Computation by the Alternative Coordinate Method

The alternative coordinate method, also known as the Shoelace Formula, is a technique for determining the area of a traverse using Cartesian coordinates. This method relies on the sequential arrangement of x and y coordinates for each point of the shape, ensuring accuracy and ease of application.In this approach, each corner's x and y coordinates are listed as fractions, with the x-coordinate as the numerator and the y-coordinate as the denominator. These coordinates are arranged sequentially...
190
Routh-Hurwitz Criterion I01:15

Routh-Hurwitz Criterion I

Consider an electrical power grid, where stability is essential to prevent blackouts. The Routh-Hurwitz criterion is a valuable tool for assessing system stability under varying load conditions or faults. By analyzing the closed-loop transfer function, the Routh-Hurwitz criterion helps determine whether the system remains stable.
To apply the Routh-Hurwitz criterion, a Routh table is constructed. The table's rows are labeled with powers of the complex frequency variable s, starting from the...
349
Bernoulli's Equation: Problem Solving01:16

Bernoulli's Equation: Problem Solving

A Venturi meter is essential for measuring fluid flow rates in pipelines. It utilizes the relationship between fluid velocity and pressure described by Bernoulli's equation. When installed in a sewage system, the Venturi meter accurately determines the wastewater flow rate by measuring pressure differences.
The first step is to compute the cross-sectional areas of the pipe and the Venturi throat to analyze the pressure difference indicated by the pressure gauge. Next, the continuity...
1.5K
Distance Corrections01:15

Distance Corrections

To achieve precise distance measurements, especially in surveying and construction, certain corrections must be applied to account for potential sources of error like the standardization errors, temperature variations, and slope adjustments.Standardization error emerges when measurement equipment undergoes changes, such as wear, repairs, or weather impacts. To address this, surveyors compare the equipment’s readings to a standard. This process identifies any deviation that might lead to...
96
Clausius-Clapeyron Equation02:35

Clausius-Clapeyron Equation

The equilibrium between a liquid and its vapor depends on the temperature of the system; a rise in temperature causes a corresponding rise in the vapor pressure of its liquid. The Clausius-Clapeyron equation gives the quantitative relation between a substance’s vapor pressure (P) and its temperature (T); it predicts the rate at which vapor pressure increases per unit increase in temperature.
59.7K