Related Experiment Video
Updated: Sep 28, 2025

Electroacupuncture Combined with Chinese Medicine Ironing Therapy for Functional Constipation
Published on: July 5, 2024
Do we need an extra dimension? A pilot study on the use of three-dimensional anorectal manometry in children with
Desiree F Baaleman1,2,3, Mana H Vriesman1,2, Marc A Benninga2
1Division of Pediatric Gastroenterology, Hepatology, and Nutrition, Department of Pediatrics, Nationwide Children's Hospital, Columbus, Ohio, USA.
Background:
Recently, a new high-definition (or three-dimensional "3D") high-resolution anorectal manometry (3D-ARM) catheter has been introduced. This catheter allows for a more detailed visualization of the anal canal. However, its clinical utility and tolerability in children with constipation are unknown. Our primary objective was to evaluate the agreement between findings from solid-state high-resolution anorectal manometry (HR-ARM) and 3D-ARM. Secondary objectives were to investigate if 3D-ARM has additional value over HR-ARM and to evaluate patient and provider experience.
Methods:
Prospective pilot study including children (8-18 years of age) with functional constipation scheduled for anorectal manometry. Children underwent HR-ARM and 3D-ARM consecutively. We compared manometry results of both procedures and collected data on patient and provider experience via self-developed questionnaires.
Key Results:
Data of ten patients were analyzed (60% female, median age 14.9 years). In the majority of patients, ARMs were performed awake (n = 8, 80%). In two patients, the recto-anal inhibitory reflex (RAIR) was visualized during HR-ARM but not during 3D-ARM. Anal canal resting pressures were significantly higher during 3D-ARM compared to HR-ARM (median 77 mmHg [IQR 59-94] vs. 69 mmHg [IQR 51-91], respectively, p = 0.037). No significant anatomical or muscular abnormalities were visualized during the 3D-ARM. The majority of children identified the 3D-ARM as the more unpleasant (5/7 [71%]) and more painful procedure (6/7 [86%]) and therefore preferred the HR-ARM (4/7 [57%]).
Conclusions & Inferences:
In our patient sample, 3D-ARM was associated with more discomfort without providing more useful information and even resulted in an inconsistent visualization of the RAIR.
More Related Videos
07:41Quantification of Levator Ani Hiatus Enlargement by Magnetic Resonance Imaging in Males and Females with Pelvic Organ Prolapse
Published on: April 17, 2019
09:44Functional Assessment of Intestinal Motility and Gut Wall Inflammation in Rodents: Analyses in a Standardized Model of Intestinal Manipulation
Published on: September 11, 2012
Related Concept Videos
Assessment of the Rectum and Anus
Rectal Inspection
Begin by inspecting the perianal and anal areas for color, texture, rashes,...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Drugs for Treatment of Constipation-Predominant IBS
Urodynamic Studies: Uroflowmetry
Imaging Studies VI: Voiding Cystourethrography and Cystography
Irritable Bowel Syndrome III: Medical and Nursing Management