Background:
We aim to compare the safety and efficacy of WEB with coiling for acutely ruptured aneurysms.METHODS: All consecutive ruptured aneurysms with width suitable for WEB (2-10 mm) treated over 5 years (1/1/2015 to 31/12/2019) were included. We recorded WFNS, Fisher grade, patient demographics and aneurysm characteristics (size, location, D/W and aspect ratio, lobulation). Primary endpoints were mRS status at 3 months, aneurysm occlusion on latest available imaging follow-up, retreatment rate and procedural complications. We applied propensity score matching using aneurysm morphology (size, D/N ratio, ASPECT ratio and lobulation) to optimise matching for WEB versus coil comparison and minimise the effects of confounding.
Result:
A total of 493 patients were identified, 97 treated with the WEB device. 1:1 propensity score matching was used to establish a matched group of 97 patients treated with coiling. The WEB arm showed 3% procedural complication rate, with no haemorrhagic complications and use of adjunctive device in 4%. Satisfactory occlusion on follow-up (mean 14 months) was 79%, with 19% retreatment rate. The coil arm had 8% complication rate, with use of an adjunctive device in 52% of cases (balloon 44%, stent 8%). Satisfactory occlusion on follow-up (mean 22 months) was 90%, with 8% retreatment rate.
Conclusion:
Treatment of ruptured wide-necked bifurcation aneurysms with WEB has a lower complication rate than coiling with high rate of satisfactory occlusion. However, there was a higher retreatment rate when compared with patients treated with coiling. An adjunct device (balloon or stent), was used in over 50% of aneurysms in the coiling group.