An Inexpensive Earth Field NMR Spectrometer with Improved Shimming
Chennagiri Rajarao Padma1, Thejas Vishnu Ramesh2, Syed Saad Siddiq2
1Medical Imaging Research Center (MIRC), Department of Medical Electronics Engineering, Dayananda Sagar College of Engineering, Bengaluru, India.
Abstract:
A simple, cost-effective, do-it-yourself earth field nuclear magnetic resonance spectrometer with shimming is demonstrated. A spectrometer for understanding magnetic resonance physics in an academic environment is presented here along with its coil and system component design. This system was designed with inexpensive and readily available electronic components costing less than US $130. The three signal chains in the system include the polarizer along with the polarization coil, transmitter driver with transceiver coil, and receiver circuit serving as a low-noise amplifier. A microcontroller acting as the signal generator and processor controls the entire system. Switching between the transmitter and the receiver is via a relay circuit. In experiments, the free induction decay obtained from the water sample lasted 2 s with an amplitude of 5 a.u. at 1512 Hz. The line width decreased by 13 Hz after active shimming compared to 3 Hz with passive shimming. The spin echo results of the commercially available Terranova-MRI system with and without sample were used as a benchmark for the low-cost earth field nuclear magnetic resonance spectrometer. The entire system had to be fine-tuned to visualize the free induction decay because the 1.2 kHz and 50 Hz noise was predominant before tuning. Future work will involve the incorporation of gradients and time-shared pulse sequence design.
More Related Videos
10:28Measuring Interactions of Globular and Filamentous Proteins by Nuclear Magnetic Resonance Spectroscopy NMR and Microscale Thermophoresis MST
Published on: November 2, 2018
07:24Paramagnetic Relaxation Enhancement for Detecting and Characterizing Self-Associations of Intrinsically Disordered Proteins
Published on: September 23, 2021
Related Concept Videos
NMR Spectrometers: Resolution and Error Correction
NMR Spectroscopy: Chemical Shift Overview
For instance, the proton...
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
NMR Spectrometers: Overview
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...