Related Experiment Video
Updated: Sep 9, 2025

MRM Microcoil Performance Calibration and Usage Demonstrated on Medicago truncatula Roots at 22 T
Published on: January 16, 2021
Fabric on fabric: A conductive fabric-based wearable coil using cutting plotter for MRI at 3T
Thejas Vishnu Ramesh1, Sergio Martin-Moreno1, Folk W Narongrit1,2
1Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana, USA.
Purpose:
Wearable coils fabricated using conductive threads have high resistance that limits SNR. The purpose of this work is to demonstrate the utility of conductive fabric as a coil conductor that can be fabricated using a cutting plotter.
Methods:
A single-channel coil was developed by feeding a conductive fabric sheet into an automatic cutting plotter. The fabric coil was loaded on a spherical phantom to evaluate SNR and B1 + homogeneity and compared with a single-channel conductive thread coil and a rigid printed circuit board (PCB) coil. A 14-channel wearable neck array was developed for structural imaging of the cervical spine and 4D flow MRI of the carotid arteries. The SNR from structural images and velocity-to-noise ratio (VNR) from flow images were compared with a 16-channel commercial coil.
Results:
The single-channel conductive fabric coil provided 6.7% and 125.9% SNR increase when compared to the rigid PCB and conductive thread coils across 10 scan repetitions. The B1 + field homogeneity was 96.4%, 1% higher than the rigid PCB and conductive thread coils. The wearable neck array demonstrated a 51.1% average SNR increase from the cervical spine images across three volunteers and a 12.0% VNR increase from the postprocessed 4D flow data when compared with the commercial 16-channel array.
Conclusion:
The possibility of developing wearable coils using conductive fabric to enhance SNR in structural images and VNR in 4D flow images is demonstrated. The conductive fabric technique enables fabrication on commercial garments resulting in form-fitting wearable coils.
More Related Videos
05:07Author Spotlight: Optimized Lung MRI Protocol with Computationally Efficient Reconstruction Methods
Published on: September 6, 2024
05:26Author Spotlight: Low-Cost Electroencephalographic Recording System Combined with a Millimeter-Sized Coil to Transcranially Stimulate the Mouse Brain In Vivo
Published on: May 26, 2023
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI
Magnetic Field Due To A Thin Straight Wire