[SNR Estimation for Image Quality Evaluation in X-ray CT]
Motohiro Tabuchi1, Takashi Kiguchi1, Hiroyuki Ikenaga2
1Department of Radiology, Konko Hospital Dojinkai.
Purpose:
Although the signal-to-noise ratio (SNR) currently used in the field of medical X-ray CT is utilized for local image evaluation in a linear system, it is not used as a comprehensive evaluation index for an entire image. Additionally, since X-ray CT cannot produce a noiseless image for obtaining the signal power required to calculate the SNR, it is impossible to calculate SNR precisely even applying the conventional method. To resolve these problems, we propose SNR*, which is a new method for calculating the estimated value of SNR that can evaluate an entire image even when the original image cannot be obtained.
Methods:
First, we obtained SNR* using the signal power and noise power calculated respectively from covariance and the difference in the pair of observed images, which are noise-containing images scanned under the same imaging conditions. Next, we verified the error and the accuracy of SNR*. Third, we demonstrated the behavior and accuracy of the SNR* applied to the actually observed image.
Results:
In the verification experiment, the relative error of SNR* concerning the true value was 0.06% or less, and the coefficient of variation value of SNR* in the demonstration experiment was 0.015 or less, which denoted the accuracy of SNR*.
Conclusion:
The proposed method realizes SNR measurement even in cases in which only observed images can be obtained and original images cannot be obtained, such as X-ray CT images.
Related Concept Videos
Radiological Investigation I: X-ray and CT
X-ray Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...