Pulse transit time-estimated blood pressure: a comparison of beat-to-beat and intermittent measurement
Satoshi Hoshide1, Akiomi Yoshihisa2,3, Fumihiro Tsuchida4
1Division of Cardiovascular Medicine, Jichi Medical University School of Medicine, Tochigi, Japan.
Abstract:
Pulse transit time (PTT), which refers to the travel time between two arterial sites within the same cardiac cycle, has been developed as a novel cuffless form of continuous blood pressure (BP) monitoring. The aim of this study was to investigate differences in BP parameters, including BP variability, between those assessed by beat-to-beat PTT-estimated BP (eBPBTB) and those assessed by intermittent PTT-estimated BP at fixed time intervals (eBPINT) in patients suspected of having sleep disordered breathing (SDB). In 330 patients with SDB (average age, 66.8 ± 11.9 years; 3% oxygen desaturation index [ODI], 21.0 ± 15.0/h) from 8 institutes, PTT-estimated BP was continuously recorded during the nighttime. The average systolic eBPBTB, maximum systolic and diastolic eBPBTB, standard deviation (SD) of systolic and diastolic eBPBTB, and coefficient variation (CV) of systolic and diastolic eBPBTB were higher than the respective values of eBPINT (all P < 0.05). Bland-Altman analysis showed a close agreement between eBPBTB and eBPINT in average systolic BP and SD and CV of systolic BP, while there were disagreements in both minimum and maximum values of eBPBTB and eBPINT in patients with high systolic BP (P < 0.05). Although systolic BP variability incrementally increased according to the tertiles of 3%ODI in both eBPBTB and eBPINT (all P < 0.05), there was no difference in this tendency between eBPBTB and eBPINT. In patients with suspected SDB, the difference between eBPBTB and eBPINT was minimal, and there were disagreements regarding both the minimum and maximum BP. However, there were agreements in regard to the index of BP variability between eBPBTB and eBPINT.
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pulse
The pulse serves as a clinical...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...