[The mid-term effect of corneal collagen cross-linking for progressive keratoconus and the changes in rigid gas permeable contact lens fitting parameters]
Related Experiment Video
Updated: Sep 27, 2025

Three Different Protocols of Corneal Collagen Crosslinking in Keratoconus: Conventional, Accelerated and Iontophoresis
Published on: November 12, 2015
1Qingdao Eye Hospital of Shandong First Medical University, Eye Institute of Shandong First Medical University, State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Qingdao 266071, China.
Abstract:
Objective: To investigate the effect of corneal collagen cross-linking (CXL) for progressive keratoconus and to evaluate changes in the parameters of rigid gas permeable contact lens (RGPCL) fitting after surgery. Methods: It was a prospective cohort study. Fifty-three eyes of 41 keratoconus patients received accelerated CXL in Qingdao Eye Hospital of Shandong First Medical University from May to December 2018. There were 31 males and 10 females, aged (20.46±4.15) years. According to the corneal thickness, de-epithelial CXL (33 eyes) or trans-epithelial CXL (20 eyes) was performed. The best spectacle-corrected visual acuity, refractive power and the thinnest corneal thickness at baseline and at 6 weeks were compared. Corneal topography was performed at baseline and at 6 weeks, 3, 6 and 12 months postoperatively. Rose K RGPCLs were used before and 6 weeks after surgery, and the fitting status was monitored until 12 months after surgery. The t test was performed to analyze the difference before and after the operation. Results: The best spectacle-corrected visual acuity, refractive power, and the thinnest corneal thickness were not significantly changed over 6 weeks of follow-up, but the Kf, Ks and Kmax values were significantly increased in all patients (all P<0.05). In the de-epithelial group, the Kmax values before the operation, at 3, 6 and 12 months after the operation were (55.00±5.51) diopters (D), (54.73±5.34) D, (54.58±6.15) D and (54.20±5.49) D, respectively, and the decrease at 12 months was significant [(0.80±2.05) D; t=2.25, P=0.001]. In the trans-epithelial group, the Kmax values were (59.43±8.98) D, (57.97±8.79) D, (58.19±8.37) D and (56.94±7.19) D at the four time points, respectively, and the decreases at 3, 6 and 12 months were all significant [(1.46±2.09) D, (1.25±1.82) D, (2.49±3.64) D; t=3.12, 3.06, 3.50; P=0.006, 0.006, 0.007]. The best RGPCL-corrected visual acuity, the diameter and the average diopters of RGPCLs showed no significant change in both groups. The RGPCL base curve decreased by 0.07 mm in the de-epithelial group and by 0.13 mm in the trans-epithelial group (both P<0.05). The design of edge lifting was used in 10 eyes postoperatively in the de-epithelial group compared with 8 eyes preoperatively, and in 4 eyes postopratively in the trans-epithelial group compared with 7 eyes preoperatively. The number of eyes using the toric peripheral design of the lens was increased to 3 compared with 2 preoperatively in the de-epithelial group and from 1 to 4 in the trans-epithelial group. The acceptance rate of RGPCL fitting in both groups increased at 6 and 12 months after surgery compared to 6 weeks after surgery. Conclusions: The corneal curvature became steep slightly at 6 weeks after CXL and gradually recovered and flattened. The Kmax in the trans-epithelial group decreased earlier and more than that in the de-epithelial group. The base curve of the RGPCLs was slightly reduced after 6 weeks, and the toric peripheral design was increasingly needed, but the requirement for the design of the lifted edge was different between the two groups. A good RGPCL fitting can be achieved within 1 year after CXL.
More Related Videos
05:56Scleral Cross-linking Using Riboflavin and Ultraviolet-A Radiation for Prevention of Axial Myopia in a Rabbit Model
Published on: April 3, 2016
12:25Second Harmonic Generation Signals in Rabbit Sclera As a Tool for Evaluation of Therapeutic Tissue Cross-linking TXL for Myopia
Published on: January 6, 2018
Related Concept Videos
Angle Closure Glaucoma: Treatment
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Focusing of Light in the Eye