A model for early failure prediction of blood pressure measurement devices in a stepped validation approach
Annina S Vischer1, Gilles Dutilh2, Thenral Socrates1
1Medical Outpatient Department and Hypertension Clinic, ESH Hypertension Centre of Excellence, University Hospital Basel, Basel, Switzerland.
Abstract:
Blood pressure monitoring (BPM) devices have to be validated according to strict international validation protocols. Each protocol requests a specific number of participants to be included. All protocols use vast amounts of resources, as three people have to be present for every measurement, making trials costly, especially when the manufacturer has no intention to execute a validation study, reflected in the low share of validated in the commercially available BPM devices. The aim of our study was to develop criteria, which could detect low accuracy devices that could not pass a validation protocol early in the course of the validation process. The 2010 European Society of Hypertension International Protocol (ESH-IP) and the Universal Standard for Validation of BPM devices (AAMI/ESH/ISO) were scrutinized for criteria which can be used for preclusion of passing. Based on this, we developed a fail model. We found that a BPM device cannot pass the ESH-IP protocol, if there are ≥27, 13, or 4 single measurements differing more than 5, 10, or 15 mmHg, respectively, from the reference. For the AAMI/ESH/ISO protocol, we developed a model, which calculates best-case standard deviations (SDs) to detect SDs which would prevent the passing of the protocol before its completion, making a stepwise validation process possible. In conclusion, we found that our model is able to predict failure of low-accuracy BPM devices early during a validation protocol if used in a stepwise-approach. This can be useful to keep costs of validation studies low and to enable investigator-initiated trials.
More Related Videos
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...