Late intraocular lens exchange in dissatisfied patients with multifocal intraocular lens implantation
Yu-Wei Kuo1, Yu-Chih Hou1,2,3
1Department of Ophthalmology, Cathay General Hospital, Taipei, Taiwan.
Abstract:
Intraocular lens (IOL) exchange may be required after multifocal IOL implantation due to dissatisfaction. Late IOL exchange is more challenging when it is done with capsulotomy. We presented a retrospective case series study enrolling four consecutive eyes reviewing late IOL exchange due to decreased vision and dysphotopsia. High residual hyperopia, astigmatism, and IOL tilt occurred in 3 eyes, respectively. The mean time to the IOL exchange was 15.8 ± 10.63 months. After separation of the adhesions by visco-dissection assisted with a 27-gaze needle and sinskey hook, IOL was explanted. One-piece IOL was implanted in the bag in two eyes without posterior capsulotomy, whereas three-piece IOL was implanted in the sulcus after viscoelastic tamponade in the other 2 eyes with capsulotomy. No complication occurred and dysphotopsia disappeared. The mean logarithm of the minimum angle of resolution best-corrected visual acuity significantly improved from 0.33 ± 0.12 preoperatively to 0.11 ± 0.13 postoperatively. In conclusion, late IOL exchange could be safely performed with proper technique and achieve good results.
Related Concept Videos
Angle Closure Glaucoma: Treatment
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Glaucoma: Overview
Focusing of Light in the Eye