Related Experiment Video
Updated: Sep 27, 2025

Fabrication of a Dipole-assisted Solid Phase Extraction Microchip for Trace Metal Analysis in Water Samples
Published on: August 7, 2016
Metal-organic framework-based magnetic dispersive micro-solid-phase extraction for the gas chromatography-mass
Fabio Fornari1, Federica Bianchi2, Nicolò Riboni1
1Università di Parma, Dipartimento di Scienze Chimiche, della Vita e della Sostenibilità Ambientale, Parco Area delle Scienze 17/A, 43124 Parma, Italy.
Abstract:
A magnetic hybrid material based on the use of the mixed-ligand Metal-Organic Framework (MOF) PUM198 is proposed for the magnetic dispersive micro solid-phase extraction (MD-μSPE) of the 16 polycyclic aromatic hydrocarbons (PAHs) included in the US-EPA priority pollutants list. PUM198 is a thermally robust MOF characterized by a doubly interpenetrated microporous framework in which Zn2+ ions and carboxylate groups define 2D planes that are pillared by a bis-pyridine-bis amide ligand containing a biphenyl scaffold. PUM198 revealed to be ideal to adsorb PAHs efficiently through non-covalent interactions. A Plackett-Burman Design followed by a Central Composite Design and the multicriteria method of the desirability functions were applied to find the optimal conditions for the extraction of the investigated PAHs, resulting in a reduced solvent consumption, i.e., 50 μL of solvent per extraction for 5 mL of sample, approximatively 3-20 times lower than those reported in previous studies, thus satisfying the principles of green analytical chemistry. Method validation proved the reliability of the method for the determination of PAHs at trace level, obtaining detection limits in the 6.7-27 ng/L range, good precision with RSDs% lower than 19% and recovery rates in the 99 (±13)-126 (±8)% range near the quantitation limit. Finally, the applicability of the method was demonstrated by analyzing underground water samples taken from contaminated sites.
More Related Videos
04:39A Modified QuEChERS-HPLC Method for Detection of Polycyclic Aromatic Hydrocarbons in Zebrafish Embryos Exposed to Fine Particulate Matter
Published on: June 13, 2025
11:59Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Extraction: Advanced Methods
High-Performance Liquid Chromatography: Types of Detectors