Artificial Thermal Ageing of Polyester Reinforced and Polyvinyl Chloride Coated Technical Fabric
Published on: January 29, 2020
Durability and Degradation of PVC-P Roofing Membrane-Example of Dynamic Fatigue Testing
1Faculty of Civil Engineering, Transportation Engineering and Architecture, University of Maribor, Smetanova ulica 17, 2000 Maribor, Slovenia.
Abstract:
This paper presents a study of PVC-P waterproofing membrane Specimens. The Specimens were taken from different segments of a flat roof after a service life of 11 years. The reason for analysing the condition of the Specimens was the apparent degradation of the waterproofing, which no longer guaranteed the watertightness of the roof. The analysis of the performance of the Specimens was based on the control of the mechanical properties, which were compared with the declared values. The mechanical properties of the degraded PVC-P waterproofing membranes with a polyester mesh backing, which are prescribed by the standards, do not usually deviate from the declared properties. This often poses a problem for liability and warranty claims due to the poor quality of the waterproofing membrane. There may be several causes of degradation of PVC-P. For this reason, in this paper, we present the possibility of controlling the properties of PVC-P waterproofing membranes using cyclic dynamic fatigue, microstructure analysis using scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS). The results show that the cause of the deterioration of the PVC-P waterproofing membranes is often related to dehydrochlorination of the polymer. However, the deterioration of the mechanical properties of the PVC-P waterproofing membranes can be successfully demonstrated by cyclic dynamic fatigue.
More Related Videos
07:15A Testing Platform for Durability Studies of Polymers and Fiber-reinforced Polymer Composites under Concurrent Hygrothermo-mechanical Stimuli
Published on: December 11, 2014
07:53Cutting Procedures, Tensile Testing, and Ageing of Flexible Unidirectional Composite Laminates
Published on: April 27, 2019
Related Concept Videos
Fatigue Strength of Concrete
Fatigue
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Yield Criteria for Ductile Materials under Plane Stress
The Maximum Shearing Stress Criterion, also known as...
Plastic Behavior
Microcracking in Concrete